Analysis of a GMR-based plethysmograph transducer and its utility for real-time Blood Pressure measurement
Abstract:
The paper presents study and analysis of a Giant Magneto Resistance (GMR)-based magneto plethysmograph and illustrates its efficacy as a tool for real-time cuff-less measurement of Blood Pressure (BP). The proposed scheme employs two GMR sensors and associated biasing and signal conditioning in its architecture. The delay between output of the GMR sensors is used to estimate the BP. The methodology, circuits and signal processing stages used are described in the paper. A prototype of the GMR-sensing solution is developed and tested. Initially, tests are carried out to determine the quality and characteristics of the plethysmographs produced by developed sensor unit, in different conditions such as various body positions, bias current etc. Good quality bio-signals were obtained during the above tests. Then, the experiments were conducted on 29 volunteers to find the feasibility of developed scheme as a BP monitor. The results obtained show that the performance of developed BP monitor is within acceptable limits.
More Related Videos
Related Concept Videos
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Measurement of Blood Pressure
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Sites for measuring blood pressure
The Brachial Artery: Primary Site for Blood Pressure Measurement
Assessment of blood pressure in brachial artery(two-step method)
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.