Development of a Telemetric, Miniaturized Electrochemical Amperometric Analyzer
Jaehyo Jung1, Jihoon Lee2, Siho Shin3
1IT Fusion Technology Research Center, Department of IT Fusion Technology, Chosun University, 309 Pilmun-daero, Dong-gu, Gwangju 61452, Korea. jh.jung207@gmail.com.
Sensors (Basel, Switzerland)
|October 26, 2017
Summary
This study presents a portable electrochemical analyzer with Bluetooth connectivity for real-time data transmission. The device accurately measures Ruthenium(III) chloride concentration, demonstrating its reliability for electrochemical analysis.
Area of Science:
- Electrochemistry
- Analytical Chemistry
- Portable Instrumentation
Background:
- Electrochemical analysis requires reliable and portable instrumentation.
- Minimizing noise interference is crucial for accurate electrochemical measurements.
- Wireless data transmission enhances the utility of analytical devices.
Purpose of the Study:
- To develop a portable, three-electrode electrochemical amperometric analyzer.
- To enable wireless data transmission to PCs and tablets via Bluetooth.
- To validate the analyzer's performance and reliability.
Main Methods:
- Utilized an indium tin oxide (ITO) glass electrode for performance validation.
- Employed a current-to-voltage (I/V) converter and digital signal processing.
- Implemented a printed circuit board (PCB) design with separated digital and analog power/ground layers to minimize noise.
Main Results:
- Developed a compact analyzer (5.9 × 3.25 cm²) with a current resolution of 0.4 nA.
- Achieved accurate measurement of Ruthenium(III) chloride concentration in a phosphate-buffered saline (PBS) solution.
- Demonstrated successful wireless data transmission to various computing devices via Bluetooth.
Conclusions:
- The developed portable electrochemical analyzer is accurate and reliable.
- The device's design effectively minimizes noise interference for enhanced performance.
- Bluetooth connectivity facilitates convenient real-time data acquisition and analysis.
Related Concept Videos
Amperometry: Overview
1.9K
Amperometry is a technique commonly used to measure the concentration of specific analytes in a solution by monitoring the electric current generated during an electrochemical reaction. It involves applying a constant potential between a working electrode and a reference electrode to measure the resulting current, which is proportional to the concentration of the analyte. The Clark oxygen electrode operates based on this principle of amperometry. It consists of a cathode and an anode enclosed...
1.9K
Controlled-Current Coulometry: Coulometric Titration
592
Coulometric titrations are a form of titrimetric analysis where the reagent is generated electrically, and its amount is evaluated based on current and generating time. The electron serves as the standard reagent. The procedure is similar to conventional titrations, such as endpoint detection.
The fundamental requirements for coulometric titrations are (1) 100% efficiency in the reagent-generating electrode reaction and (2) a stoichiometric and preferably rapid reaction between the generated...
The fundamental requirements for coulometric titrations are (1) 100% efficiency in the reagent-generating electrode reaction and (2) a stoichiometric and preferably rapid reaction between the generated...
592
Voltammetry: Overview
3.0K
Voltammetry is an electroanalytical technique in which the current flowing through an electrochemical cell is measured as a function of applied potential, typically under conditions of concentration polarization. The technique provides valuable information about redox-active species, and the current response is plotted as a voltammogram.
A voltammetric cell uses three electrodes: a working electrode, a reference electrode, and an auxiliary electrode. The redox reactions occur in the working...
A voltammetric cell uses three electrodes: a working electrode, a reference electrode, and an auxiliary electrode. The redox reactions occur in the working...
3.0K
Electrogravimetric Analysis: Overview
834
Electrogravimetric analysis measures the weight of an analyte deposited electrolytically onto a suitable working electrode. This method involves applying a potential to a pre-weighed electrode submerged in a solution, which results in the desired substance being deposited through reduction at the cathode or oxidation at the anode. The electrode's weight is recorded after deposition, and the difference in weight gives the analyte's weight in the solution.
To test the completeness of the...
To test the completeness of the...
834
Interfacial Electrochemical Methods: Overview
959
Interfacial electrochemical methods focus on the phenomena occurring at the boundary between an electrode and a solution, as opposed to bulk methods that concentrate on the solution's overall properties. These interfacial methods are classified as either static or dynamic based on the presence of a nonzero current in the electrochemical cell and the consistency of analyte concentrations. Static methods, such as potentiometry, measure the cell's potential without any significant current...
959
Electrodes: Overview
2.8K
Electrochemical measurements are conducted in an electrochemical cell composed of various components that control and measure the current and potential. One fundamental component is electrodes, conductive materials that enable electron transfer reactions at their surfaces.
There are two main types of electrodes in electrochemical cells. The first type, known as the working or indicator electrode, has a potential that is sensitive to the analyte's concentration and reacts to changes in...
There are two main types of electrodes in electrochemical cells. The first type, known as the working or indicator electrode, has a potential that is sensitive to the analyte's concentration and reacts to changes in...
2.8K