Related Experiment Video
Updated: Feb 20, 2026

Minimally Invasive Treatment for Thoracolumbar Burst Fracture Using Sagittal Alignment Screws and A Trauma Reduction Device
Published on: November 8, 2024
Skeletal stability following bioresorbable versus titanium fixation in orthognathic surgery: a systematic review and
1State Key Laboratory of Oral Diseases, National Clinical Research Centre for Oral Diseases, West China Hospital of Stomatology, Sichuan University, Wuhou District, Chengdu, Sichuan, China.
Abstract:
Despite developments in bioresorbable fixation over recent decades, controversy remains regarding skeletal stability following the use of this material in orthognathic surgery. This systematic review and meta-analysis investigated evidence from the international literature from studies comparing skeletal stability between bioresorbable and titanium fixation in orthognathic surgery. Key words were searched in MEDLINE, Embase, and Cochrane Library, and relevant journals and reference lists were searched for additional material, up to January 2017. Study quality was assessed with the Newcastle-Ottawa scale. The meta-analysis was performed using RevMan software. Ten cohort studies were included. The meta-analysis showed no statistically significant difference between bioresorbable and titanium fixation (SMD (95% CI)) for maxillary horizontal relapse (maxillary advancement 0.09 (-0.16 to 0.33); maxillary setback -0.04 (-0.64 to 0.56)), maxillary vertical relapse (maxillary elongation 0.15 (-0.31 to 0.61); maxillary impaction -0.30 (-1.10 to 0.50)), mandibular horizontal relapse (mandibular advancement 0.16 (-0.72 to 1.03); short-term mandibular setback -0.33 (-0.82 to 0.15)), and mandibular angular relapse (mandibular clockwise rotation -0.39 (-0.79 to 0.00); mandibular counter-clockwise rotation 0.14 (-0.37 to 0.66)). However, after mandibular setback, titanium fixation showed significantly less relapse in the long-term (0.97 (0.47 to 1.47)). With regard to skeletal stability, bioresorbable fixation is comparable to titanium fixation when used in maxillary setback and mandibular clockwise rotation; however titanium fixation may be preferable in mandibular setback. Further high-quality studies are needed to draw more definitive conclusions.
More Related Videos
07:35Creating Rigidly Stabilized Fractures for Assessing Intramembranous Ossification, Distraction Osteogenesis, or Healing of Critical Sized Defects
Published on: April 11, 2012
07:11Treatment of Facial Deformities using 3D Planning and Printing of Patient-Specific Implants
Published on: May 23, 2020