Related Experiment Video
Updated: Feb 19, 2026

Ultrasonography of the Adult Male Urinary Tract for Urinary Functional Testing
Published on: August 14, 2019
Urinary bladder volume measured in whole-body CT scans is a useful marker for alcohol intoxication
Denis Gümbel1, Frank Schneidler2, Matthias Frank1
1Department of Trauma, Reconstructive Surgery and Rehabilitation Medicine, University Medicine Greifswald, Ferdinand-Sauerbruch-Str., 17475 Greifswald, Germany; Department of Trauma and Orthopaedic Surgery, BG Klinikum Unfallkrankenhaus Berlin gGmbH (ukb), Warener Str. 7, 12683 Berlin, Germany.
Purpose:
The aim of this study was to investigate whether urinary bladder volume (UBV) and blood alcohol concentration (BAC) correlate in a cohort of emergency trauma patients. Furthermore, the feasibility of semi-automated 3D-CT volumetry for urinary bladder volumetry calculations in whole-body CT examinations was elucidated.
Material And Methods:
Whole-body CT scans of 831 individuals treated in the emergency department with suspected multiple injuries were included. Manual 3D-CT volumetry of the urinary bladder was performed and the mechanism of injury, patient demographics, BAC, serum creatinine, and hematocrit were retrospectively analyzed. Semi-automated calculation of UBV was performed in 30 patients. Statistical analysis included ROC analysis to calculate cut-off values, sensitivity, and specificity. The Mann-Whitney test and Spearman's correlation coefficient were used to detect significant correlations between UBV and BAC.
Results:
Manual 3D-CT volumetry showed maximum sensitivity and specificity with a cut-off value for urinary bladder volume of 416.3 mL (sensitivity 50.9%; specificity 76.3%; AUC 0.678). With a cut-off value of 4.2 mL/μmol for the creatinine quotient (quotient of serum creatinine and UBV), the sensitivity was 64.2% (specificity 67.0%; AUC 0.681). Semi-automated 3D-CT volumetry resulted in lower UBV values compared to those obtained with manual 3D-CT volumetry.
Conclusion:
Semi-automated 3D-CT volumetry is a reliable method to quantify UBV. UBV correlates with positive BAC results. A UBV above 416 mL seen on an initial whole-body CT must raise suspicion of alcohol intoxication. The creatinine quotient is an even more sensitive and specific parameter for the detection of alcohol intoxication.
Related Concept Videos
Imaging Studies VI: Voiding Cystourethrography and Cystography
Imaging Studies III: Computed Tomography
Imaging Studies I: Kidney, Ureter, and Bladder Studies
Urodynamic Studies: Uroflowmetry
Imaging Studies II: Ultrasonography
Nursing Assessment of the Genitourinary System II: Inspection and Palpation

