Related Experiment Video
Updated: Feb 19, 2026

Visualizing Lung Cellular Adaptations during Combined Ozone and LPS Induced Murine Acute Lung Injury
Published on: March 21, 2021
Associations between Ambient Fine Particulate Oxidative Potential and Cardiorespiratory Emergency Department Visits
Joseph Y Abrams1, Rodney J Weber2, Mitchel Klein3
1Department of Epidemiology, Rollins School of Public Health, Emory University, Atlanta, Georgia, USA.
Background:
Oxidative potential (OP) has been proposed as a measure of toxicity of ambient particulate matter (PM).
Objectives:
Our goal was to address an important research gap by using daily OP measurements to conduct population-level analysis of the health effects of measured ambient OP.
Methods:
A semi-automated dithiothreitol (DTT) analytical system was used to measure daily average OP (OPDTT) in water-soluble fine PM at a central monitor site in Atlanta, Georgia, over eight sampling periods (a total of 196 d) during June 2012-April 2013. Data on emergency department (ED) visits for selected cardiorespiratory outcomes were obtained for the five-county Atlanta metropolitan area. Poisson log-linear regression models controlling for temporal confounders were used to conduct time-series analyses of the relationship between daily counts of ED visits and either the 3-d moving average (lag 0-2) of OPDTT or same-day OPDTT. Bipollutant regression models were run to estimate the health associations of OPDTT while controlling for other pollutants.
Results:
OPDTT was measured for 196 d (mean=0.32 nmol/min/m3, interquartile range=0.21). Lag 0-2 OPDTT was associated with ED visits for respiratory disease (RR=1.03, 95% confidence interval (CI): 1.00, 1.05 per interquartile range increase in OPDTT), asthma (RR=1.12, 95% CI: 1.03, 1.22), and ischemic heart disease (RR=1.19, 95% CI: 1.03, 1.38). Same-day OPDTT was not associated with ED visits for any outcome. Lag 0-2 OPDTT remained a significant predictor of asthma and ischemic heart disease in most bipollutant models.
Conclusions:
Lag 0-2 OPDTT was associated with ED visits for multiple cardiorespiratory outcomes, providing support for the utility of OPDTT as a measure of fine particle toxicity. https://doi.org/10.1289/EHP1545.
Related Concept Videos
Acute Respiratory Failure-II
The underlying physiological abnormalities that contribute to hypoxemic respiratory failure include:
Chronic Obstructive Pulmonary Disease-II: Pathophysiology
Chronic Inflammation
Acute Respiratory Failure-I
Definition: It is defined by specific criteria based on blood gas measurements. Hypoxemia happens when the partial pressure of oxygen (PaO2) falls below 60 mmHg. At the same time,...
Acute Respiratory Failure-IV
Chronic Obstructive Pulmonary Disease-I: Introduction
Pulmonary Embolism I: Introduction

