Related Experiment Video
Updated: Feb 19, 2026

Crack Monitoring in Resonance Fatigue Testing of Welded Specimens Using Digital Image Correlation
Published on: September 29, 2019
Evaluation of crack status in a meter-size concrete structure using the ultrasonic nonlinear coda wave interferometry
Jean-Baptiste Legland1, Yuxiang Zhang1, Odile Abraham1
1L'Université Nantes Angers Le Mans, Institut français des sciences et technologies des transport, de l'aménagement et des réseaux, Département Géotechnique, environnement, risques naturels et sciences de la terre, Laboratoire Géophysique et Évaluation Non Destructive, CS4, F-44344 Bouguenais Cedex, France.
Abstract:
The field of civil engineering is in need of new methods of non-destructive testing, especially in order to prevent and monitor the serious deterioration of concrete structures. In this work, experimental results are reported on fault detection and characterization in a meter-scale concrete structure using an ultrasonic nonlinear coda wave interferometry (NCWI) method. This method entails the nonlinear mixing of strong pump waves with multiple scattered probe (coda) waves, along with analysis of the net effect using coda wave interferometry. A controlled damage protocol is implemented on a post-tensioned, meter-scale concrete structure in order to generate cracking within a specific area being monitored by NCWI. The nonlinear acoustic response due to the high amplitude of acoustic modulation yields information on the elastic nonlinearities of concrete, as evaluated by two specific nonlinear observables. The increase in nonlinearity level corresponds to the creation of a crack with a network of microcracks localized at its base. In addition, once the crack closes as a result of post-tensioning, the residual nonlinearities confirm the presence of the closed crack. Last, the benefits and applicability of this NCWI method to the characterization and monitoring of large structures are discussed.
Related Concept Videos
Microcracking in Concrete
Types of Non-structural Cracks in Concrete
Plastic shrinkage cracks typically form within hours after the concrete is poured. The concrete's surface dries faster than the bottom, creating tensile stress that the still-plastic concrete cannot withstand, leading to diagonal or randomly patterned cracks on the concrete surface.
Non-destructive Tests for Concrete Strength
Dynamic Modulus of Elasticity of Concrete
The sonic test is a common method to determine the dynamic modulus. In this test, a concrete beam, sized either 6 x 6 x 30 inches or 4 x 4 x 20 inches, is clamped at its center. Vibrations are initiated at one end of the beam by an electromagnetic exciter unit powered by a...
Behavior of Concrete Under Compressive Load
As the concrete specimen fractures under...
Elasticity in Concrete