Related Experiment Video
Updated: Sep 20, 2026

Quantifying Single Microvessel Permeability in Isolated Blood-perfused Rat Lung Preparation
Published on: June 30, 2014
Measurement of lung microvascular pressure in the intact anesthetized rabbit by the micropuncture technique
S Bhattacharya1, M R Glucksberg, J Bhattacharya
1St. Luke's-Roosevelt Hospital Center, New York, NY 10019.
Abstract:
We have developed a micropuncture technique for the measurement of microvascular pressure in the intact lung of rabbit. We anesthetized 16 rabbits (halothane, 0.8%) and mechanically ventilated them through a tracheotomy. Then, we exposed the right lung by rib resection over the right anterior chest. We measured pulmonary artery, left atrial, and systemic pressures by direct catheterization and cardiac output by the thermodilution technique. For micropuncture, we stabilized the lung on a shelf and stopped ventilation for 3-4 minutes at an airway pressure of 7 cm H2O. We injected pancuronium intravenously to paralyze the diaphragm and intercostal muscles. Of the total pulmonary vascular pressure drop, 52% occurred in the microvascular segment between arterioles and venules of 20 micron diameter, 28% occurred in the arterial segment, and 20% occurred in the venous segment. We conclude that in the intact lung of rabbit, the major pressure drop occurs in the microvascular segment.