Abstract:
Single-molecule imaging (SMI) has been widely utilized to investigate biomolecular dynamics and protein-protein interactions in living cells. However, multicolor SMI of intracellular proteins is challenging because of high background signals and other limitations of current fluorescence labeling approaches. To achieve reproducible intracellular SMI, a labeling probe ensuring both efficient membrane permeability and minimal non-specific binding to cell components is essential. We developed near-infrared fluorescent probes for protein labeling that specifically bind to a mutant β-lactamase tag. By structural fine-tuning of cell permeability and minimized non-specific binding, SiRcB4 enabled multicolor SMI in combination with a HaloTag-based red-fluorescent probe. Upon addition of both chemical probes at sub-nanomolar concentrations, single-molecule imaging revealed the dynamics of TLR4 and its adaptor protein, TIRAP, which are involved in the innate immune system. Statistical analysis of the quantitative properties and time-lapse changes in dynamics revealed a protein-protein interaction in response to ligand stimulation.
More Related Videos
11:06Multi-color Localization Microscopy of Single Membrane Proteins in Organelles of Live Mammalian Cells
Published on: June 30, 2018
14:09Fluorescence Biomembrane Force Probe: Concurrent Quantitation of Receptor-ligand Kinetics and Binding-induced Intracellular Signaling on a Single Cell
Published on: August 4, 2015
Related Concept Videos
Protein Dynamics in Living Cells
Fluorescent recovery after photobleaching (FRAP) is a fluorescent-protein-based detection technique used to quantify protein movement rates within the cell. This method exposes a small portion of the cell to an intense laser beam. The laser beam causes permanent photobleaching of the fluorophore-tagged proteins in the exposed region. As the bleached...
Labeling DNA Probes
Radioisotopes, fluorophores, or small molecule binding partners like biotin or digoxigenin, are the most widely used reporter tags for labeling DNA probes. These labels can be attached to the probe DNA molecule via...