Waveform analysis of deformation amplitude and deflection amplitude in normal, suspect, and keratoconic eyes
Mathew Francis1, Natasha Pahuja1, Rushad Shroff1
1From the Imaging, Biomechanics and Mathematical Modeling Solutions (Francis, Sinha Roy), Narayana Nethralaya Foundation, the Corneal and Refractive Surgery Division (Pahuja, Shroff, Gowda, Matalia, Shetty), Narayana Nethralaya, Bangalore, and the School of Biosciences and Technology (Nelson), Vellore Institute of Technology, Vellore, India.
Purpose:
To evaluate the performance of waveform-derived variables in distinguishing normal, suspect, and keratoconic eyes.
Setting:
Narayana Nethralaya Eye Hospital, Bangalore, India.
Design:
Retrospective case series.
Methods:
Scheimpflug tomography (Pentacam) and dynamic Scheimpflug analysis (Corvis ST) of 253 normal (253 patients) eyes and 205 keratoconic eyes (205 patients) were evaluated. Among the 205 patients, 62 had keratoconus in 1 eye, while the unaffected eye was suspect. From deformation amplitude, deflection amplitude and whole-eye movement were extracted. A biomechanical model was used to derive a linear (kc [constant]) and nonlinear measure (kc [mean]) of corneal stiffness. Multivariate logistic regression was performed to determine sensitivity and specificity. The analysis was validated in another dataset of 59 normal, 45 suspect, and 160 keratoconic eyes.
Results:
Deformation amplitude maximum, applanation 1 time and deformation amplitude, applanation 2 time, kc (constant), kc (mean), and deflection amplitude maximum were significantly different between normal and keratoconic eyes (P < .001). The deformation characteristics of the suspect eyes were similar to those of the keratoconic eyes, particularly grade 1 (P > .05). The kc (constant) and kc (mean) had the highest area under curve (>0.98), sensitivity, and specificity greater than 90% and 91%, respectively. Logistic regression using kc (constant) and kc (mean) improved the area to 1.0, with a sensitivity and specificity equal to 99.6% and 100%, respectively. In the validation dataset, the same cutoff yielded a sensitivity, specificity, and accuracy of 99.5%, 100%, and 99.6%, respectively.
Conclusion:
Corneal stiffness and waveform analyses could be reliable differentiators of suspect and keratoconic eyes from normal eyes.
More Related Videos
Related Concept Videos
Deformations in a Symmetric Member in Bending
When the member is segmented into tiny cubic elements, it is observed that the primary stress...
Deformation of a Beam under Transverse Loading
The insights from the bending moment diagram extend to...
Beams with Unsymmetric Loadings
The first moment-area theorem determines the slope at any point on the beam. This theorem indicates that the change in slope between two points on a beam...
Bending of Curved Members - Strain Analysis
The important part of bending analysis for such a member...
Deformation of Member under Multiple Loadings
In the case of a member with a variable cross-section, the strain is not constant but depends on the position. The deformation of an...
Normal and Shear Force