Related Experiment Video
Updated: Feb 19, 2026

An Alternative to the Traditional Cold Pressor Test: The Cold Pressor Arm Wrap
Published on: January 16, 2014
Validation of an automated bilateral feet cold pressor test
Petra Bachmann1, Xinwei Zhang1, Mauro F Larra1
1Department of Clinical Psychophysiology, Institute of Psychobiology, University of Trier, Trier, Germany.
Abstract:
The Cold Pressor Test (CPT) is often used in psychobiological research. However, the classical CPT version (unilateral hand immersion into ice-water) involves some disadvantages: hands may be needed for further applications, attentional drift towards the affected sensory hemi-field and/or physiological activation of the contralateral hemisphere may produce a laterality bias. Furthermore, instruction-induced motor activity may bias physiologic reactivity. To avoid these problems, a fully automated bilateral feet CPT was developed and tested for validity and feasibility. The test procedure is based on computerized control of water influx and efflux. This allows for maximal standardization and precise timing. Furthermore, water is kept in permanent flow to prohibit formation of stable temperature layers in skin proximity. Laterality bias, instructions effects and motor responses (e.g. lifting feet out of a water basin) are avoided. In a counterbalanced within-subject design, 28 healthy male students were exposed to the CPT and to a warm water control (CNT) condition twice, one week apart. Cardiovascular parameters, salivary cortisol and subjective ratings (stress, arousal and pain) were assessed before, during, and after interventions. The CPT profoundly affected physiology as well as subjective ratings. Expectation effects (immediately before testing) were small. Furthermore, post-CPT (presumably compensatory/counter-regulatory) effects on heart rate and stroke volume were found. In conclusion, the automated bilateral feet CPT is a valid and feasible stress test modification. Hemodynamic, subjective and endocrine stress responses are substantial, suggesting that this test version represents an advanced and suitable tool in human stress research.
More Related Videos
Related Concept Videos
Assessment of blood pressure in brachial artery(one-step method)
Prepare for the Procedure:
Assessing Blood pressure in the Leg
Preparation:
Assessment of blood pressure in brachial artery(two-step method)
Assessment of the Cardiovascular System III: Palpation
Jugular Venous Pressure (JVP) Measurement
Position the patient at a thirty- to forty-five-degree angle or in a semi-fowler's position. Look for the highest point of pulsation in the internal jugular vein and measure the vertical distance to the angle of Loius or sternal angle. A normal JVP is 3-4 cm above...
Pre-Procedural Guidelines for Assessing Blood Pressure
Sites for measuring blood pressure
The Brachial Artery: Primary Site for Blood Pressure Measurement

