The ideal fetal head circumference calculation.

A B Kurtz1, R J Kurtz

  • 1Department of Radiology, Thomas Jefferson University Hospital, Philadelphia, Pennsylvania 19107.

Journal of Ultrasound in Medicine : Official Journal of the American Institute of Ultrasound in Medicine
|January 1, 1989
PubMed
Summary
This summary is machine-generated.

Related Concept Videos

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

Grain boundary phases in bcc metals.

Nanoscale·2018
Same author

New understanding of nano-scale interstitial dislocation loops in BCC iron.

Journal of physics. Condensed matter : an Institute of Physics journal·2017
Same author

Long-time atomistic dynamics through a new self-adaptive accelerated molecular dynamics method.

Journal of physics. Condensed matter : an Institute of Physics journal·2017
Same author

Structural characterization of epitaxial Cr(x)Mo(1-x) alloy thin films.

Journal of physics. Condensed matter : an Institute of Physics journal·2012
Same author

Ab initio study of stability and migration of H and He in hcp-Sc.

Journal of physics. Condensed matter : an Institute of Physics journal·2011
Same author

Evaluation of the woman with postmenopausal bleeding: Society of Radiologists in Ultrasound-Sponsored Consensus Conference statement.

Journal of ultrasound in medicine : official journal of the American Institute of Ultrasound in Medicine·2001
Same journal

From Mechanistic Insights to Clinical Translation: Advances in the Application of Low-Intensity Pulsed Ultrasound for Osteoarthritis Treatment.

Journal of ultrasound in medicine : official journal of the American Institute of Ultrasound in Medicine·2026
Same journal

Translating AI-Based Biopsy Sparing into Clinically Actionable Decision-Making for BI-RADS 4A+ Breast Lesions.

Journal of ultrasound in medicine : official journal of the American Institute of Ultrasound in Medicine·2026
Same journal

Comparative Study of Microvascular Flow and Viscoelasticity Imaging in Monitoring Renal Allograft Function.

Journal of ultrasound in medicine : official journal of the American Institute of Ultrasound in Medicine·2026
Same journal

Deep Learning for Automated Infant Hip Ultrasound: Toward Robust Generalization across Disease Spectrum and Devices.

Journal of ultrasound in medicine : official journal of the American Institute of Ultrasound in Medicine·2026
Same journal

Ultrasound Assessment of the Fetal Pancreas in Normal and Abnormal Pregnancies: A Narrative Review.

Journal of ultrasound in medicine : official journal of the American Institute of Ultrasound in Medicine·2026
Same journal

Placental Assessment Using Microvascular Flow Imaging: Reference Ranges and Clinical Application.

Journal of ultrasound in medicine : official journal of the American Institute of Ultrasound in Medicine·2026
See all related articles

Accurate fetal head circumference measurement is crucial for predicting gestational age. New formulas minimize errors from elliptical head shapes, improving accuracy in fetal age analysis.

Area of Science:

  • Medical Imaging
  • Biometry
  • Obstetrics

Background:

  • Existing formulas for ellipse circumference introduce systematic and random errors.
  • These errors are significant in fetal head circumference (FHC) measurements, especially with increasing ellipticity (biparietal to fronto-occipital diameter ratio < 0.70).
  • Inaccurate FHC can lead to substantial errors in gestational age prediction (up to 0.8 weeks).

Purpose of the Study:

  • To analyze the shortcomings of current ellipse circumference formulas used for FHC.
  • To propose a new, simplified formula for accurate FHC calculation.
  • To improve the accuracy of fetal age analysis by minimizing measurement errors.

Main Methods:

  • Analysis of existing ellipse circumference formulas, categorizing them into circle, incorrect ellipse, and complex correct ellipse formulas.

Related Experiment Videos

  • Evaluation of systematic errors from simplified formulas and random errors from complex ones.
  • Development of a proposed formula using a correction factor based on the biparietal to fronto-occipital diameter ratio.
  • Main Results:

    • Identified systematic errors in common FHC formulas increase with head ellipticity.
    • Demonstrated potential for significant gestational age miscalculation due to these errors.
    • Proposed formula aims to reduce both systematic and random errors in FHC.

    Conclusions:

    • Current methods for FHC calculation are prone to significant errors, impacting fetal age assessment.
    • The proposed formula, incorporating a correction factor, offers a more accurate and simpler approach.
    • This improved method is expected to enhance the reliability of fetal age prediction.