Related Experiment Video
Updated: Feb 18, 2026

Continuous Telemetric In Utero Tracheal Pressure Measurements in Fetal Lambs
Published on: December 22, 2023
Tracheal cuff pressure change before and after the performance of nursing care
Lúcia Marinilza Beccaria1, Thays Marley Antonio Doimo2, Nádia Aparecida Antonia Polletti1
1Fundação Faculdade de Medicina de São José do Rio Preto, Medical School. São José do Rio Preto, São Paulo, Brazil.
Objective:
Verify the changes of endotracheal cuff pressure before and after oral hygiene, head-of-bed elevation at 0º, 30º, and 60º, change in body position, aspiration of the endotracheal tube, and in-bed bathing.
Method:
The study sample was composed of 88 patients. We performed 3,696 checks from July to September 2014.
Results:
Pressure values were analyzed in seven nursing care in the morning. Six of them were significantly altered before and after nursing procedure. In the afternoon, five of the health care provided were altered, and in the evening, only two. Most of pressure values were below recommended.
Conclusion:
There were differences before and after health care provided, showing changes in cuff pressure. In-bed bathing and head-of-bed elevation at 30º were the ones that most altered pressure values in the three working shifts. Therefore, it is necessary to measure cuff pressure at least twice per working shift, preferably after bathing.
Related Concept Videos
Tracheostomy: Procedure and Tubes
Tracheostomy tubes can be made of semiflexible plastic (polyurethane or silicone), rigid plastic, or metal, and they come in...
Endotracheal Intubation II: Nursing Management
1. Nursing Care of Patients Before Intubation
Before the endotracheal intubation procedure, nurses play an essential role in ensuring the process goes smoothly. The nurses must be familiar with intubation...
Tracheostomy Care I: Pre-procedural Steps
Required Equipment
The equipment necessary for tracheostomy care includes:
Tracheostomy Care II: Procedure
Step 1: Perform hand hygiene, and put on personal protective equipment: gown, gloves, mask...
Endotracheal Intubation I: Procedure
The ET tube comprises various components, including a standard adaptor to attach a bag-valve-mask (BVM) or ventilator, a cuff, a pilot balloon, and radiopaque markings along its length to measure the insertion distance. The tube sizes...
Pulmonary Function Tests
Pulmonary Function Tests are crucial diagnostic tools for assessing respiratory function, particularly in patients with chronic respiratory disorders. They comprehensively evaluate lung volumes, ventilatory function, breathing mechanics, diffusion, and gas exchange. These tests help diagnose pulmonary diseases and play a significant role in monitoring disease progression, evaluating disability, and assessing response to therapy.
PFTs involve using a spirometer, a...

