Related Experiment Video
Updated: Feb 18, 2026

Combined In vivo Optical and µCT Imaging to Monitor Infection, Inflammation, and Bone Anatomy in an Orthopaedic Implant Infection in Mice
Published on: October 16, 2014
Molecular imaging in musculoskeletal infections with 99mTc-UBI 29-41 SPECT/CT
Mike Sathekge1, Osvaldo Garcia-Perez2, Diana Paez3
1Department of Nuclear Medicine, University of Pretoria and Steve Biko Academic Hospital, Private Bag X169, Pretoria, 0001, South Africa. mike.sathekge@up.ac.za.
Objective:
To determine the added value of CT over planar and SPECT-only imaging in the diagnosis of musculoskeletal infection using 99mTc-UBI 29-4.
Materials And Methods:
184 patients with suspected musculoskeletal infection who underwent planar and SPECT/CT imaging with 99mTc-UBI 29-41 were included. Planar, SPECT-only and SPECT/CT images were reviewed by two independent analysts for presence of bone or soft tissue infection. Final diagnosis was confirmed with tissue cultures, surgery/histology or clinical follow-up.
Results:
99mTc-UBI 29-41 was true positive in 105/184 patients and true negative in 65/184 patients. When differentiating between soft tissue and bone infection, planar + SPECT-only imaging had a sensitivity, specificity, positive predictive value, negative predictive value and accuracy of 95.0, 74.3, 84.8, 91.3 and 86.9%, respectively, versus 99.0, 94.5, 92.5, 98.5 and 94.5% for SPECT/CT. SPECT/CT resulted in a change in reviewers' confidence in the final diagnosis in 91/184 patients. Inter-observer agreement was better with SPECT/CT compared with planar + SPECT imaging (kappa 0.87, 95% CI 0.71-0.85 versus kappa 0.81, 95% CI 0.58-0.75).
Conclusion:
Addition of CT to planar and SPECT-only imaging led to an increase in diagnostic performance and an improvement in reviewers' confidence and inter-observer agreement in differentiating bone from soft tissue infection.
More Related Videos
07:48High Spatial Resolution Chemical Imaging of Implant-Associated Infections with X-ray Excited Luminescence Chemical Imaging Through Tissue
Published on: September 30, 2022
09:55Radiosynthesis, Quality Control, and Small Animal Positron Emission Tomography Imaging of 68Ga-Labelled Nano Molecules
Published on: October 4, 2024
Related Concept Videos
Magnetic Resonance Imaging
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET
Imaging Studies IV: Magnetic Resonance Imaging
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...
Imaging Studies III: Computed Tomography
Ultrasonography
During an ultrasonography procedure, a handheld device called...