Summary
The open Seldinger-guided technique for axillary artery cannulation is a safe and effective method for thoracic aortic surgery. This approach offers speed and simplicity, minimizing risks of limb ischemia and local complications.
Area of Science:
- Cardiovascular Surgery
- Vascular Surgery
- Thoracic Surgery
Background:
- Axillary artery cannulation is a common approach in thoracic aortic surgery, often using a sidearm graft.
- Femoral cannulation is preferred institutionally, but axillary cannulation is used selectively for patients with specific imaging findings.
- The open Seldinger-guided technique has been routinely employed since 2011 for axillary cannulation.
Purpose of the Study:
- To evaluate the safety and efficacy of the open Seldinger-guided technique for axillary artery cannulation.
- To report institutional experience with this specific cannulation method.
Main Methods:
- Retrospective analysis of 404 peripheral arterial cannulations for thoracic aortic surgery (2011-2016).
- Identified 52 axillary cannulations performed using the open Seldinger-guided technique.
- Technique involves surgical exposure and guidewire cannulation without arterial incision.
Main Results:
- Axillary cannulations were performed for ascending and/or arch surgery.
- Hospital survival rate was 98.1% (51/52).
- No axillary arterial injury, intraoperative malperfusion, postoperative limb ischemia, stroke, wound infections, or late pseudoaneurysms were observed.
Conclusions:
- The open Seldinger-guided technique for axillary artery cannulation is safe and effective.
- The technique is recommended due to its speed, simplicity, and reduced risk of complications.