Related Experiment Video
Updated: Feb 18, 2026

Automated Hydrophobic Interaction Chromatography Column Selection for Use in Protein Purification
Published on: September 21, 2011
Hydroxamate column-based purification of zirconium-89 (89Zr) using an automated fluidic platform
Matthew J O'Hara1, Nathaniel J Murray1, Jennifer C Carter1
1Nuclear Sciences Division, Pacific Northwest National Laboratory, 902 Battelle Blvd., PO Box 999, Richland, WA 99352, USA.
Abstract:
Zirconium-89 (89Zr) is a long-lived (t1/2 = 78.4h) positron-emitting isotope that is useful for positron emission tomography (PET) based diagnostic imaging using radiolabeled antibodies. Hydroxamate resin columns are predominantly used for the purification of 89Zr from cyclotron bombarded natY targets dissolved in strong HCl. 89Zr is conventionally eluted from the resin in 1M oxalic acid (H2C2O4), a complexant that is conducive to follow-on binding of 89Zr through a transchelation process to the deferoxamine siderophore. In the present study, we determined that a lower concentration of H2C2O4 eluent (0.8M) is adequate to efficiently remove 89Zr from a column containing 100mg hydroxamate resin. As a result, less buffering agents are needed to be added to the 89Zr product fraction prior to labeling. A simple automated fluidic system prototype has been developed to perform the steps required for 89Zr purification using a hydroxamate resin column (column conditioning in HCl, Y target dissolution, dissolved target solution load onto column, column washes using HCl and water, and 89Zr elution). The system performance was evaluated using several cyclotron bombarded Y targets; 89Zr product fractions demonstrated excellent chemical recoveries from these targets, with 1.0mL product volumes yielding 89±2% of the column elution peak activity and 84±2% of 89Zr recovered from the target (at EOB). These results compare favorably with previously published 89Zr product volumes and yields, despite the lower concentration of H2C2O4 eluent employed. Transchelation of resulting 89Zr product fractions was performed to assess product quality. The effective specific activity (ESA) ranged between 44(7) and 109(22) TBq·mmole-1, while the bindable metals concentration, a metric introduced for assessing and comparing product purity, ranged between 43(7) and 115(27) nmole·g-1.
Related Concept Videos
Ion-Exchange Chromatography
Ion Exchange
Types Of Column Chromatography
Gel Filtration Chromatography
When the...
Silica Gel Column Chromatography: Overview
Polar components tend to bind strongly to the silica gel, causing them to move slowly through the column. In contrast, nonpolar compounds...
Principles Of Column Chromatography

