Quasistatic Mechanical Testing for Computer-Aided Design and Manufacturing Occlusal Veneers Cemented to Milled Dentin Analog Material
Published on: December 20, 2024
Shear bond strength of different materials used as core build-up to ceramic
Bledar Lilaj1, Alexander Franz1, Viktoria Dangl2
1Department of Conservative Dentistry & Periodontology, Medical University of Vienna, Vienna, Austria.
Purpose:
To determine the performance of a resin composite material specially developed for core build-ups in comparison with conventional restorative materials.
Methods:
90 roughened ceramic blocs were divided into three groups; one group (n=30) was used for the core build-up material (Gradia Core) and the other two groups (n=30, each) were used for two conventional restorative materials (Tetric EvoCeram, Compoglass F). After adhesive fixation, specimens of each material were subdivided in accordance with the storage conditions (thermocycling or water storage). Shear bond strength was measured and fracture behavior was analyzed.
Results:
Gradia Core presented significantly higher shear bond strength values than the conventional restorative material Tetric EvoCeram, both after 24 hours water storage as well as after thermocycling. Compoglass F did not show any statistically significant differences compared to the other materials, independent of the storage condition. However, Compoglass F resulted in numerically higher shear bond values than Tetric EvoCeram, but lower shear bond values than Gradia Core. Within the same materials, no statistically significant differences occurred regarding the storage conditions.
Clinical Significance:
The specific core build-up material provided stronger bonding properties when luted to feldspar ceramic than conventional restorative materials, making it a suitable supporting material when high-quality esthetic restorations are needed for restoring decayed, but vital teeth.
Related Concept Videos
Bonding and Strength of Aggregate
Strength of Cement
For compressive strength tests, ASTM C 109-05 standards prescribe a cement-sand mix ratio of 1:2.75 and a water/cement ratio of 0.485 for making 2-inch cubes. These cubes are mixed, cast, and cured in saturated lime water at 23°C until testing. Flexural strength testing, outlined in...
Porosity in Cement Paste
The balance of water to cement in the mix is...
Impact Strength of Concrete
Tensile Strength Considerations of Concrete
The dimensions and shape of a concrete specimen...
Toughness and Hardness of Aggregate