Related Experiment Video
Updated: Feb 18, 2026

Quasistatic Mechanical Testing for Computer-Aided Design and Manufacturing Occlusal Veneers Cemented to Milled Dentin Analog Material
Published on: December 20, 2024
Effect of finishing technique on the occurrence and length of microcracks in resin-based materials
Adalberto B de Vasconcellos1,2, Alex Delgado3, Ronaldo Hirata4
1Operative Dentistry, School of Dentistry, Fluminense Federal University, Nova Friburgo, RJ, Brazil.
Purpose:
To evaluate the presence and length of microcracks in resin-based materials finished with different techniques, using optical coherence tomography (OCT).
Methods:
Standardized Class V preparations (3x2x2mm) were made in the facial and lingual surfaces of 20 recently-extracted human third molars. 20 preparations were restored with a resin-based composite material (RBC; Filtek Supreme Ultra) and the other 20 with a resin-modified glass-ionomer material (RMGI; Ketac Nano). After final polymerization, specimens were further stratified by finishing system: aluminum oxide discs (Sof-Lex) or spiral fluted carbide bur series (H48L). By random allocation, each extracted tooth therefore received one RBC and one RMGI restoration, and equal numbers of restorations from each material were finished using each finishing system (n= 10). After 24 hours of storage in 100% humidity at room temperature, the specimens were evaluated at x20 to x600 under environmental SEM. Cross-sectional occlusal-cervical B-mode images were obtained in increments of 25 mm from the mesial margin to the distal margin of the restoration using a spectral-domain (SD) OCT system and analyzed using Image J software to identify and measure microcrack penetration into each restoration. The total length (mm) at the point of the deepest microcrack penetration in each specimen was recorded. Data were statistically analyzed using a t-test.
Results:
No microcracks were observed in the RBC samples. However, microcrack presence was identified in all of the RMGI specimens. The t-test showed a statistically significant difference (P< 0.05) in mean microcrack length values based on the finishing technique used for the RMGI samples. [SofLex: 0.67 (± 0.28) mm; carbide: 1.26 (± 0.30)] mm. Two-way ANOVA showed significant differences in the factors "finishing technique" and "restorative material" (P< 0.001). The interaction of these two factors was also statistically significant (P< 0.001). For the tested RMGI, Tukey post-hoc test revealed that the finishing with aluminum oxide groups resulted in statistically significant lower mean microcrack length when compared to spiral fluted carbide burs (P< 0.001).
Clinical Significance:
Resin-modified glass-ionomer (RMGI) is more susceptible to microcrack presence than resin-based composites. Also, aluminum oxide discs produced lower values of mean microcrack length than spiral fluted carbide burs after the finishing procedure of RMGI restorations.
Related Concept Videos
Microcracking in Concrete
Fatigue
Types of Non-structural Cracks in Concrete
Plastic shrinkage cracks typically form within hours after the concrete is poured. The concrete's surface dries faster than the bottom, creating tensile stress that the still-plastic concrete cannot withstand, leading to diagonal or randomly patterned cracks on the concrete surface.
Tensile Strength Considerations of Concrete
The dimensions and shape of a concrete specimen...

