Beta-2 microglobulin clearance in high-flux dialysis and convective dialysis modalities: a meta-analysis of published
Maria-Eleni Roumelioti1, Gregory Trietley2,3, Thomas D Nolin2,3
1Nephrology Division, Department of Medicine, University of New Mexico, Albuquerque, NM, USA.
Background:
Recent meta-analyses suggest that higher removal of beta-2 microglobulin (β2M) with either high-flux (HFD) dialysis or hemodiafiltration (HDF) may be associated with decreased total and cardiovascular mortality in dialysis patients. However, there are limited data about the performance of high flux dialyzers and/or convective therapies in removing β2M.
Methods:
This is a random effects meta-analysis and meta-regression of data extracted from randomized controlled trials and observational studies in hemodialysis, hemofiltration and HDF regarding the efficiency of high flux dialyzers to remove β2M. Studies were searched using ProQuest in SCOPUS, EMBASE and MEDLINE.
Results:
We included 69 studies from 1 January 2001 to 12 June 2017 on 1879 patients with 6771 available measurements. Average β2M clearance was 48.75 mL/min [95% confidence interval (CI) 42.50-55.21] for conventional HF dialysis, and 87.06 mL/min (95% CI 75.08-99.03) for convective therapies (hemofiltration and HDF) with substantial heterogeneity among studies [P (Q) ≤ 0.001]. In multivariable meta-regression analyses, we found significantly higher β2M clearance for polyarylethersulfone dialyzers when used for HFD and polysulfone membranes in convective therapies. However, the mass of β2M removed into the dialysate did not depend on membrane material. Adjusted dialysate-side (-22.279, 95% CI -9.8 to -34.757, P < 0.001) β2M clearances were significantly lower than whole blood clearances, suggesting that adsorption contributes substantially to β2M removal. Higher Kuf, blood flow and substitution fluid rates but not dialysate flow rates were associated with statistically significant and clinically meaningful elevation in β2M clearance from the body independent of the dialysis modality.
Conclusions:
Membrane composition and characteristics, modality (convective versus diffusive), blood flow rates and substitution fluid rates in HDF play a significant role in the efficient removal of β2M from the body in both diffusive and convective dialysis.
Related Concept Videos
Renal Drug Clearance: Comparison Between Renal Excretion Methods
Renal clearance is often associated with the renal glomerular filtration rate (GFR), which represents the rate at which plasma is filtered through the glomeruli in the kidney. When drug reabsorption is minimal and there is no active secretion, renal clearance is closely related to the...
Renal Drug Clearance: Overview
Renal clearance can be calculated using different methods. One approach is to divide the urinary drug excretion rate by the plasma drug concentration. This method directly measures renal clearance, indicating the kidneys' efficiency in...
Drug Dosing in Renal Diseases: Dose Adjustments Based on Drug Clearance and Elimination Rate Constant
Drug Dosing in Renal Diseases: Measurement of Serum Creatinine Concentration and Clearance
Renal Clearance
Renal clearance refers to the volume of plasma cleared of a specific substance, such as creatinine, per unit of time. To measure clearance, urine samples are collected over a 24-hour period during each bladder voiding, followed by a single blood sample at the...
Drug Dosing in Renal Diseases: Estimation of Glomerular Filtration Rate Based on Serum Creatinine Concentration