Identifying Coronary Artery Calcification on Non-gated Computed Tomography Scans
Published on: August 28, 2018
Tin-filtered low-dose chest CT to quantify macroscopic calcification burden of the thoracic aorta
Christoph Schabel1,2, Daniele Marin3, Dominik Ketelsen4
1Department of Diagnostic and Interventional Radiology, University Hospital of Tuebingen, Hoppe-Seyler-Strasse 3, 72076, Tuebingen, Germany. chschabel@gmx.de.
Objectives:
To compare a low-dose, tin-filtered, nonenhanced, high-pitch Sn100 kVp CT protocol (Sn100) with a standard protocol (STP) for the detection of calcifications in the ascending aorta in patients scheduled for cardiac surgery.
Methods:
Institutional Review Board approval for this retrospective study was waived and the study was HIPAA-compliant. The study included 192 patients (128 men; age 68.8 ± 9.9 years), of whom 87 received the STP and 105 the Sn100 protocol. Size-specific dose estimates (SSDE) and radiation doses were obtained using dose monitoring software. Two blinded readers evaluated image quality on a scale from 1 (low) to 5 (high) and the extent of calcifications of the ascending aorta on a scale from 0 (none) to 10 (high), subdivided into 12 anatomic segments.
Results:
The Sn100 protocol achieved a mean SSDE of only 0.5 ± 0.1 mGy and 0.20 ± 0.04 mSv compared with the mean SSDE of 5.4 ± 2.2 mGy achieved with the STP protocol (p < 0.0001). Calcification burden was associated with age (p < 0.0001), but was independent of protocol with mean calcification scores of 0.48 ± 1.23 (STP) and 0.55 ± 1.25 (Sn100, p = 0.18). Reader agreement was very good (STP κ = 0.87 ± 0.02, Sn100 κ = 0.88 ± 0.01). The STP protocol provided a higher subjective image quality than the Sn100 protocol: STP median 4, interquartile range 4-5, vs. SN100 3, 3-4; p < 0.0001) and a slightly better depiction of calcification (STP 5, 4-5, vs. Sn100 4, 4-5; p < 0.0001).
Conclusions:
The optimized Sn100 protocol achieved a mean SSDE of only 0.5 ± 0.1 mGy while the depiction of calcifications remained good, and there was no systematic difference in calcification burden between the two protocols.
Key Points:
• Tin-filtered, low-dose CT can be used to assess aortic calcifications before cardiac surgery • An optimized Sn100 protocol achieved a mean SSDE of only 0.5 ± 0.1 mGy • The depiction of atherosclerosis of the thoracic aorta was similar with both protocols • The depiction of relevant thoracic pathologies before cardiac surgery was similar with both protocols.
More Related Videos
08:02Author Spotlight: Enhanced Quantification of Cardiovascular Calcification Progression for Longitudinal Micro PET/CT Studies in Small Research Animals
Published on: November 15, 2024
08:43Calcification of Vascular Smooth Muscle Cells and Imaging of Aortic Calcification and Inflammation
Published on: May 31, 2016
Related Concept Videos
Imaging Studies for Cardiovascular System VI: Calcium -Scoring CT
Imaging Studies for Cardiovascular System V: CT
Imaging Studies for Cardiovascular System III: X-Ray
Definition and Purpose
An X-ray, or radiograph, is a non-invasive method that uses ionizing radiation to take images of internal structures. It is mainly used in cardiac imaging to examine the heart, lungs, and major blood vessels, aiming to identify abnormalities in the heart's size, shape, and position, such as heart failure, congenital defects, and vascular...
Aneurysm II: Clinical Manifestations and Diagnostic Studies