Related Experiment Video
Updated: Jan 15, 2026

Novel In Vivo Micro-Computed Tomography Imaging Techniques for Assessing the Progression of Non-Alcoholic Fatty Liver Disease
Published on: March 24, 2023
Adult Abdominal Photon-Counting CT Protocols: A Multiinstitutional Consensus of the Society of Abdominal Radiology
Bari Dane1, Lakshmi Anathakrishnan2, Daniele Marin3
1Department of Radiology, NYU Langone Health, 660 1st Ave, 3rd Fl, New York, NY 10016.
Abstract:
Photon-counting CT (PCCT) offers new opportunities for abdominal imaging by enabling higher spatial resolution, improved image quality, and reduced radiation exposure compared with conventional energy-integrating detector CT systems. However, standardized PCCT protocols for abdominal imaging are lacking, which limits clinical adoption, comparability across institutions, and multicenter research studies. The Society of Abdominal Radiology (SAR) Photon-Counting Detector CT Emerging Technology Commission created a survey to achieve consensus on common adult abdominal PCCT protocols for FDA-approved PCCT, including portal venous phase CT, multiphase aortic CTA, and multiphase pancreas CT protocols. The survey included the following items for each protocol: scan mode, tube potential, image quality level, primary viewing virtual monoenergetic imaging (VMI) level, reconstruction kernel, additional VMI or other spectral reconstructions sent to PACS, and details of archiving the special spectral imaging dataset. Consensus statements were generated based on the survey and voted on by nine radiologists from nine institutions using the consensus-minus-one method. Consensus was reached for 20 protocol features, including that 70-keV VMI is recommended for primary interpretation of portal venous and multiphase pancreas PCCT and that, for multiphase aortic CTA, low virtual monoenergetic levels should be viewed. This multiinstitutional consensus endorsed by SAR establishes standardized abdominal PCCT protocols.
Related Concept Videos
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Imaging Studies III: Computed Tomography
Imaging Studies for Cardiovascular System V: CT
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body...
Radiological Investigation I: X-ray and CT
X-ray Imaging

