Design of a Biocompatible Drug-Eluting Tracheal Stent in Mice with Laryngotracheal Stenosis
Published on: January 21, 2020
Experimental use of new absorbable tracheal stent
Luciano F Schopf1, José Carlos Fraga2, Rodrigo Porto3
1Pediatric Surgeon at Hospital de Clínicas of Porto Alegre, Brazil; Federal University of Rio Grande do Sul, Porto Alegre, Brazil.
Background/Purpose:
Silicone and metallic stents are not effective in children with tracheobronchial stenosis or tracheomalacia. Herein, we aimed to evaluate the clinical manifestations and histological reaction of rabbit trachea to the presence of a new poly(lactic-co-glycolic acid) with polyisoprene (PLGA/PI) polymer absorbable stent.
Methods:
Fourteen adult white rabbits (weight, 3.0-3.5kg) were randomly assigned to three groups: Group I (n=6): PLGA/PI spiral stent; Group II (n=6): PLGA/PI fragment; and Group III (n=2): controls. After a longitudinal incision on three cervical tracheal rings, the stents and fragments were inserted into the trachea and fixed onto the lateral wall with nonabsorbable sutures.
Results:
The stented group showed significantly more stridor at rest (p=0.0041), agitation (p=0.014), and use of accessory muscles (p=0.0002) and required more emergency endoscopies than the fragment group. Further, it showed significantly more remarkable histological inflammatory damage than the fragment and control groups (p=0.002).
Conclusions:
The new PLGA/PI polymeric stent implanted into the trachea of rabbits caused more clinical manifestations and histologically verified inflammatory reaction than the PLGA/PI polymeric fragment. Future studies should be aimed at reducing the stent-wall thickness.
Related Concept Videos
Tracheostomy: Procedure and Tubes
Tracheostomy tubes can be made of semiflexible plastic (polyurethane or silicone), rigid plastic, or metal, and they come in...
Tracheostomy Decannulation
Description of the Procedure
Decannulation refers to the permanent removal of the tracheostomy tube, signaling the resolution of the condition that initially necessitated the tracheostomy. The process requires a well-coordinated interplay between...
Tracheostomy Care II: Procedure
Step 1: Perform hand hygiene, and put on personal protective equipment: gown, gloves, mask...
Tracheostomy Care I: Pre-procedural Steps
Required Equipment
The equipment necessary for tracheostomy care includes:
Tracheostomy Suctioning II: Procedure
Trachea
Anatomical Features:
Location: About half of the trachea is situated in the neck, anterior to the esophagus, and extends from the larynx (at the level of...