Semiautomatic algorithm to remove resonance artifacts from the direct radial artery pressure
1Department of Anesthesiology, University of Washington, Seattle.
Abstract:
Resonance artifacts introduced by the catheter-manometer system are removed from the direct radial artery pressure using a three-step algorithm. First, the fast-flush method is used to identify the natural frequency and damping coefficient of the monitoring system by digitizing and analyzing the pressure transient created by the flush. Second, resistor, capacitor, and inductor values are found for an RLC second-order model of the catheter-manometer system in use. Third, the algorithm predicts the undistorted radial artery pressure, removing the resonance artifacts by inverse-filtering the digitized monitored pressure waveform using the RLC circuit derived previously. The algorithm was implemented using a personal computer, but it could also be used without the computer by incorporating an analog-to-digital convertor and a microprocessor in the hemodynamic monitor.
Related Concept Videos
Assessment of radial pulse
The radial pulse, located at the wrist, is often the preferred site for assessing peripheral pulse because of its accessibility and dependability. The process of determining the radial pulse involves several steps:
Assessment of apical radial pulse
The A-R pulse assessment involves simultaneous evaluation of the apical and radial pulses. When the apical and radial pulse rates vary, this assessment helps identify a pulse deficit.
Pre-Procedural Preparation
Sites for measuring blood pressure
The Brachial Artery: Primary Site for Blood Pressure Measurement
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...