Related Experiment Video
Updated: Feb 16, 2026

Measurements of Soil Carbon by Neutron-Gamma Analysis in Static and Scanning Modes
Published on: August 24, 2017
COMPARING TWO MEASUREMENTS OF THE SAME COSMIC-RAY NEUTRON SPECTRUM USING STANDARD BONNER SPHERES AND HIGH-SENSITIVITY
Kuo-Wei Lee1,2, Rong-Jiun Sheu1,3
1Institute of Nuclear Engineering and Science, National Tsing Hua University, Hsinchu, Taiwan, ROC.
Abstract:
Ground-level cosmic-ray neutron spectra in Taiwan were measured using two neutron spectrometers, standard Bonner spheres and homemade high-sensitivity Bonner cylinders. The Bonner sphere system consisted of 12 polyethylene spheres of various diameters and four extended-range spheres that contained embedded metal shells. A set of 16 similarly designed Bonner cylinders was assembled based on a large cylindrical 3He proportional counter, showing an efficiency ~18 times higher than that of the central probe of the Bonner spheres. However, these Bonner cylinders were not fully symmetrical and exhibited angular dependence in their responses to incoming neutrons. Focusing on the low-intensity neutron background, this study presents a systematic comparison between Bonner spheres and cylinders in terms of their response characteristics, counting statistics, and unfolded neutron spectra. The comparison indicated that the neutron probe of the Bonner spheres had a small but non-negligible counting noise that required subtraction from the recorded data. According to the response functions calculated for isotropic neutron incidence, the neutron spectrum determined using the high-sensitivity Bonner cylinders agreed well with that measured using the Bonner spheres. The annual effective doses from cosmic-ray neutrons at the location were determined to be 30.5 and 30.8 μSv by using the Bonner sphere and cylinder spectrometers, respectively, which corresponded to respective total neutron fluxes of 5.39 × 10-3 and 5.43 × 10-3 cm-2s-1.
More Related Videos
06:28Visualization of Low-Level Gamma Radiation Sources Using a Low-Cost, High-Sensitivity, Omnidirectional Compton Camera
Published on: January 30, 2020
10:10Neutron Crystallography Data Collection and Processing for Modelling Hydrogen Atoms in Protein Structures
Published on: December 1, 2020
Related Concept Videos
2D NMR: Overview of Homonuclear Correlation Techniques
COSY90 is the standard two-dimensional (2D) COSY experiment that...
2D NMR: Overview of Heteronuclear Correlation Techniques
NMR Spectrometers: Resolution and Error Correction
¹³C NMR: ¹H–¹³C Decoupling
A broadband decoupling technique is used to simplify these complex, sometimes overlapping, signals. Broadband decoupling relies on a...
High-Resolution Mass Spectrometry (HRMS)
Atomic Emission Spectroscopy: Lab