The effect of trabeculectomy on contrast sensitivity, corneal topography and aberrations
Fereshteh Abolbashari1,2, Asieh Ehsaei3,4, Ramin Daneshvar5
1Refractive Errors Research Center, Mashhad University of Medical Sciences, Mashhad, Iran.
Purpose:
To investigate the effect of trabeculectomy on corneal topography, corneal sensitivity and aberrations.
Methods:
Twenty-four eyes of 24 subjects with open-angle glaucoma who required glaucoma filtration surgery were assessed. The evaluation of corneal topography, corneal sensitivity and aberrations were done before the trabeculectomy procedure, 1 week and 1 month after the trabeculectomy.
Results:
There were significant differences in cylindrical power (P = 0.02), contrast sensitivity at 12 cycle/degree spatial frequency (P = 0.04) as well as high order aberration (P = 0.04) and high order without spherical component (P = 0.02) following trabeculectomy. However, significant differences were found for keratometric results and Fourier index in 3 and 6 mm pupil diameters between pre- and post-trabeculectomy (P > 0.05).
Conclusions:
According to the findings of the current study, trabeculectomy affects contrast sensitivity at 12 cycle/degree spatial frequency, higher-order aberration and higher order without spherical component aberration 1 month after trabeculectomy. Being knowledgeable about these changes may lead to some advancement in post-surgical management of patients particularly in early stages following trabeculectomy.
Related Concept Videos
Methods of Obtaining Topography
Phase Contrast and Differential Interference Contrast Microscopy
In-phase-contrast microscopes, interference between light directly passing through a cell and light refracted by cellular components is used to create high-contrast, high-resolution images without staining. It is the oldest and simplest type of microscope that creates an image by altering the wavelengths of light rays passing through the specimen. Altered wavelength paths are created using an annular stop in the condenser. The annular stop produces a hollow cone of...
Sensitivity, Specificity, and Predicted Value
Sensitivity is the...
Sputum Studies II: Culture and Sensitivity
Sputum culture and sensitivity is a medical procedure used to diagnose bacterial infections in the respiratory tract and select the most appropriate antibiotics for treatment. This process involves analyzing sputum samples of thick and opaque secretions produced in the lungs and airways. These samples are collected from patients and then sent to the laboratory for analysis.
The test can identify various pathogens responsible for respiratory infections, including Streptococcus,...
Urine Studies II: Urine Culture and Sensitivity Test
Local Anesthetics: Differential Sensitivity of Nerve Fibers