Normal Reference Ranges for Transthoracic Echocardiography Following Heart Transplantation
Annika Ingvarsson1, Anna Werther Evaldsson1, Johan Waktare2
1Department of Clinical Sciences Lund, Cardiology, Lund University, Lund, Sweden; Section for Heart Failure and Valvular Disease, VO Heart and Lung Medicine, Skane University Hospital, Lund, Sweden.
Background:
Heart function following heart transplantation (HTx) is influenced by numerous factors. It is typically evaluated using transthoracic echocardiography, but reference values are currently unavailable for this context. The primary aim of the present study was to derive echocardiographic reference values for chamber size and function, including cardiac mechanics, in clinically stable HTx patients.
Methods:
The study enrolled 124 healthy HTx patients examined prospectively. Patients underwent comprehensive two-dimensional echocardiographic examinations according to contemporary guidelines. Results were compared with recognized reference values for healthy subjects.
Results:
Compared with guidelines, larger atrial dimensions were seen in HTx patients. Left ventricular (LV) diastolic volume was smaller, and LV wall thickness was increased. With respect to LV function, both ejection fraction (62 ± 7%, P < .01) and global longitudinal strain (-16.5 ± 3.3%, P < .0001) were lower. All measures of right ventricular (RV) size were greater than reference values (P < .0001), and all measures of RV function were reduced (tricuspid annular plane systolic excursion 15 ± 4 mm [P < .0001], RV systolic tissue Doppler velocity 10 ± 6 cm/sec [P < .0001], fractional area change 40 ± 8% [P < .0001], and RV free wall strain -16.9 ± 4.2% [P < .0001]). Ejection fraction and LV global longitudinal strain were significantly lower in patients with previous rejection.
Conclusion:
The findings of this study indicate that the distribution of routinely used echocardiographic measures differs between stable HTx patients and healthy subjects. In particular, markedly larger RV and atrial volumes and mild reductions in both LV and RV longitudinal strain were evident. The observed differences could be clinically relevant in the assessment of HTx patients, and specific reference values should be applied in this context.
More Related Videos
09:05Transthoracic Speckle Tracking Echocardiography for the Quantitative Assessment of Left Ventricular Myocardial Deformation
Published on: October 20, 2016
08:19Transthoracic Echocardiography to Assess Post-Resuscitation Left Ventricular Dysfunction After Acute Myocardial Infarction and Cardiac Arrest in Pigs
Published on: July 12, 2022
Related Concept Videos
Variation: Normal Distribution, Range, and Standard Deviation
Range
15.9; 16.1; 15.2; 14.8; 15.8; 15.9; 16.0; 15.5
Measurements of the amount of soda in a 16-ounce can vary since different subjects record these measurements or since the exact amount - 16 ounces of liquid, was not...
Inertial Frames of Reference
Non-inertial Frames of Reference
Normal Distribution
Normal Stress
When a rod is under axial loading, the internal forces and corresponding stress are normal to the plane of the section, so it is termed normal stress. It's important to...