Related Experiment Video
Updated: Feb 16, 2026

Novel Sequence Discovery by Subtractive Genomics
Published on: January 25, 2019
Characteristics of percutaneous core biopsies adequate for next generation genomic sequencing
Sharjeel H Sabir1, Savitri Krishnamurthy2, Sanjay Gupta1
1Department of Interventional Radiology, The University of Texas MD Anderson Cancer Center, Houston, Texas, United States of America.
Purpose:
Determine the characteristics of percutaneous core biopsies that are adequate for a next generation sequencing (NGS) genomic panel.
Materials And Methods:
All patients undergoing percutaneous core biopsies in interventional radiology (IR) with samples evaluated for a 46-gene NGS panel during 1-year were included in this retrospective study. Patient and procedure variables were collected. An imaging-based likelihood of adequacy score incorporating targeting and sampling factors was assigned to each biopsied lesion. Univariate and multivariate logistic regression was performed.
Results:
153 patients were included (58.2% female, average age 59.5 years). The most common malignancy was lung cancer (40.5%), most common biopsied site was lung (36%), and average size of biopsied lesions was 3.8 cm (+/- 2.7). Adequacy for NGS was 69.9%. Univariate analysis showed higher likelihood of adequacy score (p = 0.004), primary malignancy type (p = 0.03), and absence of prior systemic therapy (p = 0.018) were associated with adequacy for NGS. Multivariate analysis showed higher adequacy for lesions with likelihood of adequacy scored 3 (high) versus lesions scored 1 (low) (OR, 7.82; p = 0.002). Melanoma lesions had higher adequacy for NGS versus breast cancer lesions (OR 9.5; p = 0.01). Absence of prior systemic therapy (OR, 6.1; p = 0.02) and systemic therapy = 3 months (OR 3.24; p = 0.01) compared to systemic therapy >3 months before biopsy yielded greater adequacy for NGS. Lesions <3 cm had greater adequacy for NGS than larger lesions (OR 2.72, p = 0.02).
Conclusion:
As targeted therapy becomes standard for more cancers, percutaneous biopsy specimens adequate for NGS genomic testing will be needed. An imaging-based likelihood of adequacy score assigned by IR physicians and other pre-procedure variables can help predict the likelihood of biopsy adequacy for NGS.
Related Concept Videos
The Nucleosome Core Particle
The paradox
Nucleosomes, paradoxically, perform two opposite functions simultaneously. On the one hand, their main responsibility is to protect the delicate DNA strands from physical damage and help achieve a higher compaction ratio. While on the other hand, they must allow polymerase enzymes to access DNA...
Next-generation Sequencing
Next-Generation Sequencing Methods
Although all next-generation methods use different technologies, they all share a set of standard features....
Genomics
Genomic Imprinting and Inheritance
The expression of some genes depends on which parent passed the gene to the offspring, through a phenomenon known as...
Characteristics of Life
Genome Size and the Evolution of New Genes

