Related Experiment Video
Updated: Feb 16, 2026

Microfluidic Production of Lysolipid-Containing Temperature-Sensitive Liposomes
Published on: March 3, 2020
Drug release kinetics of temperature sensitive liposomes measured at high-temporal resolution with a millifluidic
Caitlin Burke1, Matthew R Dreher2, Ayele H Negussie3
1a Department of Bioengineering , George Mason University , Fairfax , VA , USA.
Purpose:
Current release assays have inadequate temporal resolution ( ∼ 10 s) to characterise temperature sensitive liposomes (TSL) designed for intravascular triggered drug release, where release within the first few seconds is relevant for drug delivery.
Materials And Methods:
We developed a novel release assay based on a millifluidic device. A 500 µm capillary tube was heated by a temperature-controlled Peltier element. A TSL solution encapsulating a fluorescent compound was pumped through the tube, producing a fluorescence gradient along the tube due to TSL release. Release kinetics were measured by analysing fluorescence images of the tube. We measured three TSL formulations: traditional TSL (DPPC:DSPC:DSPE-PEF2000,80:15:5), MSPC-LTSL (DPPC:MSPC:DSPE-PEG2000,85:10:5) and MPPC-LTSL (DPPC:MMPC:PEF2000,86:10:4). TSL were loaded with either carboxyfluorescein (CF), Calcein, tetramethylrhodamine (TMR) or doxorubicin (Dox). TSL were diluted in one of the four buffers: phosphate buffered saline (PBS), 10% bovine serum albumin (BSA) solution, foetal bovine serum (FBS) or human plasma. Release was measured between 37-45 °C.
Results:
The millifluidic device allowed measurement of release kinetics within the first few seconds at ∼5 ms temporal resolution. Dox had the fastest release and highest release %, followed by CF, Calcein and TMR. Of the four buffers, release was fastest in human plasma, followed by FBS, BSA and PBS.
Conclusions:
The millifluidic device allows measurement of TSL release at unprecedented temporal resolution, thus allowing adequate characterisation of TSL release at time scales relevant for intravascular triggered drug release. The type of buffer and encapsulated compound significantly affect release kinetics and need to be considered when designing and evaluating novel TSL-drug combinations.
More Related Videos
11:31Targeting Drugs to Larval Zebrafish Macrophages by Injecting Drug-Loaded Liposomes
Published on: February 18, 2020
07:47Custom-designed Laser-based Heating Apparatus for Triggered Release of Cisplatin from Thermosensitive Liposomes with Magnetic Resonance Image Guidance
Published on: December 13, 2015
Related Concept Videos
Kinetic Molecular Theory: Molecular Velocities, Temperature, and Kinetic Energy
Assessing Body Temperature - Temporal Artery
Step 1: Perform hand hygiene and don a fresh pair of gloves to prevent cross-infection and ensure patient safety.
Step 2: Explain the procedure to the patient to establish trust. Clear communication establishes trust with the patient, ensures they understand what to expect, promotes cooperation, and enhances comfort during the procedure.
Step 3: Assess the patient's...
¹H NMR of Labile Protons: Temporal Resolution
The –OH proton in alcohols typically appears in the range of δ 2 to 5 ppm but can vary depending on the specific...
Kinetics of Drug Elimination
Drug clearance depends on the rate of drug elimination and its plasma concentration. Another important parameter is the half-life of a drug, which is the time required for its concentration to decrease by half. In most cases, drug clearance follows first-order...
Modified-Release Drug Delivery Systems: Drug Release Characteristics
¹H NMR of Conformationally Flexible Molecules: Temporal Resolution