Human in-vivo brain magnetic resonance current density imaging (MRCDI)

Cihan Göksu1, Lars G Hanson1, Hartwig R Siebner2

  • 1Danish Research Centre for Magnetic Resonance, Centre for Functional and Diagnostic Imaging and Research, Copenhagen University Hospital Hvidovre, Denmark; Center for Magnetic Resonance, DTU Elektro, Technical University of Denmark, Kgs Lyngby, Denmark.

Neuroimage
|December 31, 2017
PubMed

Related Concept Videos

Magnetic Resonance Imaging01:24

Magnetic Resonance Imaging

Magnetic resonance imaging (MRI) is a noninvasive medical imaging technique based on a phenomenon of nuclear physics discovered in the 1930s, in which matter exposed to magnetic fields and radio waves was found to emit radio signals. In 1970, a physician and researcher named Raymond Damadian noticed that malignant (cancerous) tissue gave off different signals than normal body tissue. He applied for a patent for the first MRI scanning device in clinical use by the early 1980s. The early MRI...
9.9K
Current Density01:21

Current Density

The total amount of current flowing through one unit value of a cross-sectional area is referred to as current density. If the current flow is uniform, the amount of current flowing through a conductor is the same at all points along the conductor, even if the conductor area varies. The current density consists of the local magnitude and direction of the charge flow, which varies from point to point. Current density is measured in amperes per meter square, and direction is defined as the net...
5.2K
Imaging Studies IV: Magnetic Resonance Imaging01:27

Imaging Studies IV: Magnetic Resonance Imaging

Introduction:Magnetic Resonance Imaging, or MRI, can include a specialized imaging technique of the urinary system known as Magnetic Resonance Urography (MRU). This radiation-free technique uses strong magnetic fields and radio waves to produce detailed images with the help of a computer. MRU is particularly effective for visualizing fluid-filled structures like the kidneys, ureters, and bladder.Applications of MRI in the Genitourinary SystemKidneys and Ureters: MRI detects tumors, cysts,...
296
Boundary Conditions for Current Density01:25

Boundary Conditions for Current Density

Current density becomes discontinuous across an interface of materials with different electrical conductivities. The normal component of the current density is continuous across the boundary.
1.4K
Magnetic Force Between Two Parallel Currents01:13

Magnetic Force Between Two Parallel Currents

Two long, straight, and parallel current-carrying conductors exert a force of equal magnitude on one another. The direction of the force depends on the current direction in the conductors.
The force exerted by the magnetic field due to the first conductor over a finite length of the second conductor is given as the product of the current in the second conductor and  the vector product of the length vector along the current element and the field due to the first conductor. According to the...
4.7K
Magnetic Field Of A Current Loop01:16

Magnetic Field Of A Current Loop

Consider a circular loop with a radius a, that carries a current I. The magnetic field due to the current at an arbitrary point P along the axis of the loop can be calculated using the Biot-Savart law.
6.4K