Related Experiment Video
Updated: Feb 16, 2026

Terahertz Microfluidic Sensing Using a Parallel-plate Waveguide Sensor
Published on: August 30, 2012
Design and development of compact coaxial to coplanar waveguide directional coupler for HPM measurement
Xinhong Cui1, Xiaolong Wu2, Zhengfeng Xiong2
1Department of Electronic Engineering and Information Science, University of Science and Technology of China, Hefei 230027, China.
Abstract:
A compact, high-directivity, weak-coupling directional coupler with coaxial-coplanar waveguide structure and diamond-shaped coupling slot was developed at L band for a high-power microwave measurement by both theoretical analysis and experiments. The relation between the dimension of the coupling slot and the characteristic parameters of the coupler was studied by the small-hole coupling theory and the infinitesimal method. According to the analysis results, the directivity could be better than 20 dB while the length of the slot is just less than a single λ because of the use of the diamond coupling slot. For demonstration, a 45-dB L band coaxial-coplanar waveguide directional coupler was designed and verified by test. The experiment results and the theoretical analysis are in good agreement, which indicates that in the range of 1-2 GHz, the coupling was approximately -45 dB and the directivity was better than 17 dB. The power-handling capacity was demonstrated to reach 2 MW with a length (150 mm) of less than λ and a cross section (46 mm × 55 mm) of less than one-twelfth of the BJ-14 waveguide directional coupler.
Related Concept Videos
Coplanar Forces
Compact Bone
Compact bone, also called cortical bone, is the denser, stronger of the two types of bone tissue. It is found under the periosteum and in the diaphyses of long bones, where it provides support and protection. The microscopic structural unit of compact bone is called an osteon, or haversian system. Each osteon is composed of concentric rings of calcified...
Compacting Factor test
The procedure begins by placing concrete into the upper hopper without any compaction. Once filled, the bottom door of this hopper is opened,...
Design Example: Measuring Distance Between Two Points with Obstructions
Energy Stored In A Coaxial Cable
In the simplest form, a coaxial cable can be represented by two long hollow concentric cylinders in which the current flows in opposite directions. The magnetic field inside and outside the coaxial cable is determined by using Ampère's law. The magnetic field inside...
Group Design

