[Kinetic cluster and α-divergence-based dynamic myocardial factorial analysis of positron-emission computed
Pei-Pei Wang1, Li-Jun Lu, Shuang-Liang Cao
1Guangdong Provincial Key Laboratory of Medical Image Processing, School of Biomedical Engineering, Southern Medical University, Guangzhou 510515, China.
Objective:
We purpose a novel factor analysis method based on kinetic cluster and α-divergence measure for extracting the blood input function and the time-activity curve of the regional tissue from dynamic myocardial positron emission computed tomography(PET) images.
Methods:
Dynamic PET images were decomposed into initial factors and factor images by minimizing the α-divergence between the factor model and actual image data. The kinetic clustering as a priori constraint was then incorporated into the model to solve the nonuniqueness problem, and the tissue time-activity curves and the tissue space distributions with physiological significance were generated.
Results:
The model was applied to the 82RbPET myocardial perfusion simulation data and compared with the traditional model-based least squares measure and the minimal spatial overlap constraint. The experimental results showed that the proposed model performed better than the traditional model in terms of both accuracy and sensitivity.
Conclusion:
This method can select the optimal measure by α value, and incorporate the prior information of the kinetic clustering of PET image pixels to obtain the accurate time-activity curves of the tissue, which has shown good performance in visual evaluation and quantitative evaluation.
More Related Videos
09:34Dynamic Imaging of Chimeric Antigen Receptor T Cells with [18F]Tetrafluoroborate Positron Emission Tomography/Computed Tomography
Published on: February 17, 2022
10:21Continuous Blood Sampling in Small Animal Positron Emission Tomography/Computed Tomography Enables the Measurement of the Arterial Input Function
Published on: August 8, 2019
Related Concept Videos
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body...
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET
Imaging Studies III: Computed Tomography
Factorial Design
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Divergence and Curl