Related Experiment Video
Updated: Feb 16, 2026

Voluntary Breath-hold Technique for Reducing Heart Dose in Left Breast Radiotherapy
Published on: July 3, 2014
Unintended doses in radiotherapy-over, under and outside?
David J Eaton1,2, John P Byrne2,3, Vivian P Cosgrove4
11 National Radiotherapy Trials Quality Assurance Group (RTTQA), Mount Vernon Hospital , Northwood , UK.
Serious incidents in radiotherapy are reported nationally to improve patient safety. New UK legislation expands reporting to include underexposures and positioning errors, enhancing safety culture.
Area of Science:
- Medical Physics
- Radiation Oncology
- Healthcare Safety
Background:
- National reporting of serious incidents in radiotherapy is crucial for identifying potential harm and safety culture issues.
- Current UK guidance primarily addresses overexposures, but new legislation will encompass underexposures and positioning errors.
Purpose of the Study:
- To review current UK guidance on reporting serious incidents in radiotherapy.
- To propose practical approaches for addressing underexposures and positioning errors in incident reporting.
- To discuss the definition and implementation of a local error margin.
Main Methods:
- Review of existing UK radiotherapy safety guidance.
- Analysis of implications of new legislation regarding underexposures and positioning errors.
- Discussion of practical strategies for defining and applying local error margins.
Main Results:
- Radiotherapy is a safe treatment, but incident reporting is vital for continuous improvement.
- New legislation broadens the scope of reportable incidents to include underexposures and positioning errors.
- Practical approaches for defining local error margins are needed to manage these new categories.
Conclusions:
- Expanded incident reporting in radiotherapy enhances patient safety and safety culture.
- Clear definitions and practical application of error margins are essential for effective implementation of new guidance.
- Proactive management of radiotherapy incidents, including underexposures and positioning errors, is key to maintaining high safety standards.
Related Concept Videos
Dose Size and Dosing Frequency: Determination Methods
Determination of Multiple Dosing Parameters: Loading and Maintenance Doses
Rational Dosage Regimen: Maintenance Dose and Loading Dose
In most cases, drugs are administered repetitively or infused continuously to maintain a steady-state concentration in the body. At a steady...
Drug Dosing: Infants and Children
Drug Dosing: Geriatric Patients
Dose-Response Relationship: Overview

