Use of an Integrated Low-Flow Anesthetic Vaporizer, Ventilator, and Physiological Monitoring System for Rodents
Published on: July 9, 2020
EVALUATION OF BLOOD GAS VALUES IN ANESTHETIZED SOUTHERN WHITE RHINOCEROS ( CERATOTHERIUM SIMUM) VENTILATED WITH A
Abstract:
Rhinoceros conservation efforts are essential to the survival of the species. One such effort is focused on using advanced reproductive technologies to produce viable northern white rhinoceros ( Ceratotherium simum cottoni) embryos for implantation into southern white rhinoceros ( Ceratotherium simum simum) surrogates. Anesthesia may be required to facilitate necessary procedures in these surrogate rhinoceros, but commonly reported side effects including hypercapnia and hypoxemia limit anesthetic recumbency time due to animal safety concerns. Although many interventions have been attempted, success in improving these physiologic parameters to date is mixed. The objective of this report is to describe arterial pH (pHa), blood gas (PaO2 and PaCO2), bicarbonate, base excess, lactate, and cardiovascular (heart rate, direct arterial blood pressure) values recorded in seven intubated and ventilated female southern white rhinoceros anesthetized for reproductive examinations in a zoological park setting. Anesthetic induction was accomplished using etorphine, medetomidine, butorphanol, and midazolam. The primary hypotheses were that PaO2 and PaCO2 would improve after intubation and mechanical ventilation. Induction and recovery observations were also summarized. Physiologic and laboratory data were analyzed using a mixed linear regression model using ranks. Statistical significance was set at P < 0.05. The PaO2 increased significantly ( P < 0.001) following ventilation from a median value of 58 (range, 38-67) to 123 (range, 42-184) mm Hg. The PaCO2 significantly ( P = 0.003) decreased from 63 (range, 55-73) to 52 (range, 30-75) mm Hg, with a corresponding improvement ( P = 0.068) in pHa from 7.33 (7.25-7.34) to 7.37 (7.24-7.58) units. Intubation and ventilation improve respiratory parameters and may facilitate safe prolongation of anesthetic duration in white rhinoceros.
Related Concept Videos
Mechanical Ventilation I: Indication and Settings
Mechanical Ventilation II: Invasive Ventilation
Negative-Pressure Ventilators
Negative-pressure ventilators create a vacuum around the chest or body to draw air into the lungs, simulating breathing. This method does not require an...
Mechanical Ventilation III: Noninvasive Ventilation
Noninvasive Positive-Pressure Ventilation...
Factors Affecting Pulmonary Ventilation
Alveolar Surface Tension
The alveolar fluid lines the luminal surface of the alveoli and exerts a force called surface tension. This force is caused by the polar water molecules in the liquid being more strongly attracted to each...
Pulmonary Ventilation: Inhalation
Boyle's law becomes particularly pertinent when examining respiratory...
Assessment of Ventilation I: Respiratory Rate
A Ventilation assessment is critical for monitoring a patient's health status. Respiration, one of the most accessible vital signs, provides insights into the function of numerous body systems and can indicate serious health issues, such as brainstem injuries from head trauma.
Critical Guidelines for Assessing Ventilation: