Related Experiment Video
Updated: Feb 16, 2026

Echocardiographic Evaluation of Atrial Communications before Transcatheter Closure
Published on: February 8, 2022
Echocardiographic evaluation and guidance for MitraClip procedure
William E Katz1, Anson J Conrad Smith1, Frederick W Crock1
1Division of Cardiovascular Diseases, Department of Medicine, UPMC Heart & Vascular Institute, University of Pittsburgh, Pittsburgh, PA, USA.
Transcatheter mitral valve repair with the MitraClip system is a proven treatment for severe mitral regurgitation in high-risk patients. This review details patient selection, imaging, and procedural guidance for optimal outcomes.
Area of Science:
- Cardiovascular Medicine
- Interventional Cardiology
- Medical Imaging
Background:
- Transcatheter mitral valve repair (TMVR) using the MitraClip system is a key therapy for severe mitral regurgitation (MR).
- It is indicated for symptomatic patients with prohibitive surgical risk.
- The MitraClip system offers a less invasive alternative to conventional surgery.
Purpose of the Study:
- To provide a comprehensive review of clinical and imaging aspects for MitraClip therapy.
- To guide patient selection, imaging evaluation, and intraprocedural techniques.
- To offer an updated framework based on current literature and clinical experience.
Main Methods:
- Literature review of clinical studies and imaging techniques for MitraClip.
- Analysis of patient selection criteria for TMVR.
- Evaluation of echocardiographic and other imaging modalities for procedural guidance.
Main Results:
- The MitraClip system is a well-established, worldwide therapeutic option.
- Optimal patient selection and imaging are crucial for successful outcomes.
- Experienced practitioners can achieve excellent results with this device.
Conclusions:
- MitraClip therapy is a valuable tool for managing severe mitral regurgitation in high-risk patients.
- A thorough understanding of clinical and imaging parameters enhances procedural success.
- This review provides a current framework for practitioners utilizing this transcatheter approach.
Related Concept Videos
Blind Procedures
Handwashing II: Pre-procedure and Initial Procedure Steps
The hand washing procedure itself includes the following steps. First, cover cuts, if any, on hands with a waterproof dressing. Cuts and abrasions can become contaminated with bacteria hindering the ability to clean the area thoroughly. In addition, repeated hand washing can worsen an injury. The nails must be short and clean, without nail...
Handwashing III: During the Procedure and Post-Procedure Steps
Self-Evaluation: Self-Enhancement and Self-Verification
Hemodialysis II: Procedure and Complications
Tracheostomy: Procedure and Tubes
Tracheostomy tubes can be made of semiflexible plastic (polyurethane or silicone), rigid plastic, or metal, and they come in...