Related Experiment Video
Updated: Feb 16, 2026

In vivo Structural Assessments of Ocular Disease in Rodent Models using Optical Coherence Tomography
Published on: July 24, 2020
Intraoperative changes in corneal structure during excimer laser phototherapeutic keratectomy (PTK) assessed by
Sebastian Siebelmann1, Jens Horstmann2,3, Paula Scholz2
1Department of Ophthalmology, University of Cologne, Kerpener Strasse 62, 50924, Cologne, Germany. sebastian.siebelmann@uk-koeln.de.
Purpose:
Excimer laser phototherapeutic keratectomy (PTK) is a safe treatment for superficial corneal opacities, e.g., in corneal dystrophies or degenerations. Nevertheless, no standardized treatment protocols are available and intraoperative monitoring was not possible, so far. Here we evaluate the potential benefits of the intraoperative assessment by microscope-integrated intraoperative optical coherence tomography (MI-OCT) of corneal optical properties during PTK.
Methods:
Retrospective study of eight patients (one male, seven females; age range, 43-80 years, mean = 66.1 years) using an 840-nm microscope-integrated spectral-domain OCT (iOCT; OptoMedical Technologies, Luebeck, Germany adapted to HS Hi-R Neo 900A, Haag Streit Surgical, Wedel, Germany). Images were acquired before and after corneal abrasion and after PTK. For PTK, a SCHWIND Amaris 750S excimer laser (SCHWIND eye-tech-solutions GmbH und KO. KG) was used. Parameters assessed were the central corneal thickness (CCT), changes in central depth-dependent corneal tissue intensity (TI), and corneal surface roughness (SR) in cross-sectional images of the cornea.
Results:
Intraoperative monitoring using microscope-integrated OCT was possible in all patients at all time points. TI of the anterior corneal stroma decreased significantly (p = 0.037) after PTK (T1 = 15.1 ± 3.6, T2 = 15.0 ± 3.84, T3 = 13.7 ± 3.38), but not after corneal abrasion alone, indicating increased transparency caused by excimer laser PTK. CCT was significantly lower after corneal abrasion (p = 0.017), but not after PTK (T1 = 630.4 ± 70 μm, T2 = 544.1 ± 59.4 μm, T3 = 558.3 ± 52.5 μm. SR significantly decreased (p = 0.043) after PTK (T1 = 614.4 ± 37.5 pixels, T2 = 634.4 ± 35.6 pixels, T3 = 611.0 ± 40.3 pixels).
Conclusions:
Intraoperative OCT allows real-time imaging during PTK and the assessment of corneal optical transparency and its surface roughness. It has to be clarified in larger studies if these parameters correlate with later postoperative visual outcomes.
Related Concept Videos
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Structures of Solids
Structural Isomerism
Isomers are different chemical species that have the same chemical formula. Structural isomerism of coordination compounds can be divided into two subcategories, the linkage isomers and coordination-sphere isomers.
Linkage isomers occur when the coordination compound contains a ligand that can bind to the transition metal center through two different atoms. For example, the CN− ligand can bind through the carbon atom or through the nitrogen atom. Similarly, SCN− can...
Structure of Lipids
Viral Structure
Antibody Structure
Antibodies, also known as immunoglobulins (Ig), are essential players of the adaptive immune system. These antigen-binding proteins are produced by B cells and make up 20 percent of the total blood plasma by weight. In mammals, antibodies fall into five different classes, which each elicits a different biological response upon antigen binding.
The Y-Shaped Structure of Antibodies Consists of Four Polypeptide Chains
Antibodies consist of four polypeptide chains: two identical heavy...

