Related Experiment Video
Updated: Feb 16, 2026

Intraoperative Ultrasound in Spinal Surgery
Published on: August 17, 2022
Use of Intraoperative Computed Tomography in Craniomaxillofacial Trauma Surgery
Karl Cuddy1, Baber Khatib2, R Bryan Bell3
1Assistant Professor and Director of Education and Maxillofacial Trauma, Division of Oral and Maxillofacial Surgery, University of Toronto, Toronto, Ontario, Canada, and Fellow, Advanced Craniomaxillofacial Surgery and Trauma (2016-2017), Legacy Emanuel Medical Center, Head and Neck Institute, Portland, OR.
Purpose:
The use of technology to aid in assessment, planning, and management of complex craniomaxillofacial injuries is increasingly common. Preoperative computed tomography (CT) evaluation is considered the standard of care, and intraoperative imaging is becoming increasingly accessible. Limited data exist regarding the implication of intraoperative CT on decision making in the management of all sites of facial fractures. The purposes of this study were to characterize the use of an intraoperative CT scanner for craniomaxillofacial surgery within our institution, to quantify the effect of intraoperative CT on surgical decision making, and to attempt to provide guidance on when to use this technology.
Patients And Methods:
This retrospective case series characterizes the use of an intraoperative CT scanner for craniomaxillofacial trauma surgery at a level 1 trauma center in Portland, Oregon, from February 2011 to September 2016. We evaluated the following variables: the number of intraoperative CT scans performed for craniomaxillofacial surgery including the number of scans for each patient, the number of scans for each operative visit, the CT-directed revision rate (overall and for specific preoperative diagnoses), and the indication for imaging. This information was evaluated to provide guidance on appropriate use of an intraoperative scanner.
Results:
A total of 161 patients were identified to have intraoperative facial CT scans from February 2011 to September 20, 2016, at Legacy Emanuel Medical Center. A total of 212 intraoperative facial CT scans were performed across 168 separate operations. The overall CT-directed revision rate was 28%. CT-directed revision rates for fracture subsites are as follows: orbital, 31%; zygomaticomaxillary complex, 24%; Le Fort I, 8%; Le Fort II and III, 23%; naso-orbital-ethmoidal, 23%; mandible, 13%; and frontal sinus, 0%. No CT-directed revisions were performed during removal of hardware, during placement of craniofacial implants, or in temporomandibular joint replacement surgery.
Conclusions:
If available, intraoperative CT should be routinely considered in the operative management of orbital fractures and pan-facial fractures, as well as complex zygomaticomaxillary complex, Le Fort II and III, and naso-orbital-ethmoidal fractures. Consideration also should be given to the use of intraoperative CT in cases of complex mandible fractures involving severe comminution or the condylar region. Intraoperative CT should not be routinely used for the management of Le Fort I fractures or frontal sinus fractures.
More Related Videos
Related Concept Videos
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Imaging Studies III: Computed Tomography
Design Example: Traverse Angle Computations
Area Computation by the Alternative Coordinate Method
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body...
The Role of Ion Channels in Neuronal Computation
Sometimes a single EPSP is strong enough to induce an action potential in the postsynaptic neuron. However, multiple presynaptic inputs must often create EPSPs around the same time for the postsynaptic neuron to be sufficiently depolarized to fire an action potential....