Contrast ultrasound is a widely used clinical tool to obtain real-time qualitative blood flow assessments in the heart, liver, etc. Echocardiographic particle image velocimetry (echo-PIV) is a technique for obtaining quantitative velocity maps from contrast ultrasound images. However, unlike optical particle image velocimetry (PIV), routine echo images are prone to nonuniform spatiotemporal variations in tracer distribution, making analysis difficult for standard PIV algorithms. This study introduces optimized procedures that integrate image enhancement, PIV, and particle tracking velocimetry (PTV) to obtain reliable time-resolved two-dimensional (2D) velocity distributions. During initial PIV analysis, multiple results are obtained by varying processing parameters. Optimization involving outlier removal and smoothing is used to select the correct vector. These results are used in a multiparameter PTV procedure. To demonstrate their clinical value, the procedures are implemented to obtain velocity and vorticity distributions over multiple cardiac cycles using images acquired from four left ventricular thrombus (LVT) patients. Phase-averaged data elucidate flow structure evolution over the cycle and are used to calculate penetration depth and strength of left ventricular (LV) vortices, as well as apical velocity induced by them. The present data are consistent with previous time-averaged results for the minimum vortex penetration depth associated with LVT occurrence. However, due to decay and fragmentation of LV vortices, as they migrate away from the mitral annulus, in two cases with high penetration, there is still poor washing near the resolved clot throughout the cycle. Hence, direct examination of entire flow evolution may be useful for assessing risk of LVT relapse before prescribing anticoagulants.
Related Concept Videos
Subatomic Particles
The Nucleosome Core Particle
The paradox
Nucleosomes, paradoxically, perform two opposite functions simultaneously. On the one hand, their main responsibility is to protect the delicate DNA strands from physical damage and help achieve a higher compaction ratio. While on the other hand, they must allow polymerase enzymes to access DNA...
The Nucleosome Core Particle
Nucleosomes, paradoxically, perform two opposite functions simultaneously. On the one hand, their primary aim is to protect the delicate DNA strands from physical damage and help achieve a higher compaction ratio. On the other hand, they must allow polymerase enzymes to access histone-bound DNA during...
Basic Postulates of Kinetic Molecular Theory: Particle Size, Energy, and Collision
Equilibrium Conditions for a Particle
To understand the concept of equilibrium, let us first consider the forces acting on an object. When different forces act on an object, they can...
Principle of Linear Impulse and Momentum for a System of Particles
Notably, internal forces between particles, occurring in equal and opposite collinear pairs, cancel out and are not part of the equation of motion. This exclusion simplifies the...