Related Experiment Video
Updated: Feb 15, 2026

Pretreatment of Lignocellulosic Biomass with Low-cost Ionic Liquids
Published on: August 10, 2016
Fast and easy extraction of antidepressants from whole blood using ionic liquids as extraction solvent
Marieke De Boeck1, Lisa Dubrulle1, Wim Dehaen2
1Toxicology and Pharmacology, Department of Pharmaceutical and Pharmacological Sciences, University of Leuven (KU Leuven), Campus Gasthuisberg, O&N II, P.O. Box 922, Herestraat 49, 3000 Leuven, Belgium.
Abstract:
This study aims to prove that ionic liquids (ILs) can be used as extraction solvents in a liquid-liquid microextraction, coupled to LC-MS/MS, for the quantification of a large group of antidepressants in whole blood samples. The sample preparation procedure consisted of adding 1.0mL aqueous buffer pH 3.0 and 60µL of IL (1-butyl-3-methylimidazolium hexafluorophosphate) to 1.0mL whole blood. Subsequently, a 5-min rotary mixing step was performed followed by centrifugation. The lower IL phase was collected, diluted 1:10 in methanol and 10µL was injected into the LC-MS/MS. The following analytes were included in the full-quantitative method: agomelatine, amitriptyline, bupropion, clomipramine, dosulepin, doxepin, duloxetine, escitalopram, fluoxetine, imipramine, maprotiline, mianserin, mirtazapine, nortriptyline, paroxetine, reboxetine, trazodone and venlafaxine. Selectivity was checked for 10 different whole blood matrices. Additionally, possible interferences of deuterated standards or other antidepressants were evaluated. Overall, no interferences were found. For each analyte a matrix-matched calibration curve was constructed (7 levels, n = 6), covering therapeutic and low toxic concentrations. Accuracy and precision were evaluated over eight days, at three concentration levels (n = 2). Bias, repeatability and intermediate precision results met with the proposed validation criteria, except for fluvoxamine, which was therefore only included in the semi-quantitative method. LOQs were set at the lowest calibrator concentration and LOD values were - for most analytes - within a range of 1-2ng/mL. Recoveries (RE) and matrix effects (ME) were evaluated for five types of donor whole blood, at two concentration levels. RE values were within a range of 53.11-132.98%. ME values were within a range of 61.92-123.24%. In conclusion, this study proves the applicability of ILs as extraction solvents for a large group of antidepressants in complex whole blood matrices.
More Related Videos
13:35A Convenient Method for Extraction and Analysis with High-Pressure Liquid Chromatography of Catecholamine Neurotransmitters and Their Metabolites
Published on: March 1, 2018
06:45Author Spotlight: Optimizing Hollow-Fiber Membranes for Continuous Liquid-Liquid Extraction of Medium-Chain Fatty Acids
Published on: August 9, 2024
Related Concept Videos
Solvents
A...
Extraction: Effects of pH
Extraction: Advanced Methods
Solubility of Ionic Compounds
Ionic Radii
Ionic Bonds
When atoms gain or lose electrons to achieve a more stable electron configuration they form ions. Ionic bonds are electrostatic attractions between ions with opposite charges. Ionic compounds are rigid and brittle when solid and may dissociate into their constituent ions in water. Covalent compounds, by contrast, remain intact unless a chemical reaction breaks them.
Opposing Charges Hold Ions Together in Ionic Compounds
Ionic bonds are reversible electrostatic interactions between ions...