Related Experiment Video
Updated: Feb 15, 2026

Autoradiography as a Simple and Powerful Method for Visualization and Characterization of Pharmacological Targets
Published on: March 12, 2019
A Simple Non-invasive I-123-IMP Autoradiography Method Developed by Modifying the Simple Non-invasive I-123-IMP
Asato Ofuji1, Rieko Nagaoka1,2, Kosuke Yamashita3
1Graduate School of Health Sciences, Kumamoto University, Kumamoto, Japan.
Objectives:
We developed a simple non-invasive I-123-N-isopropyl-p-iodoamphetamine (123I-IMP) quantification method by analyzing chest RI-angiography and single photon emission computed tomography (SPECT) images based on the microsphere model (SIMS method). Theoretically, the SIMS method could be changed to the simple non-invasive ARG (SIARG) method by modifying the integrated washout ratio (WR) to one-point WR. If the regional cerebral blood flow (rCBF) values derived from the SIARG and ARG methods correlate well, the facilities employing the ARG method can easily switch to the SIARG method. The purpose of this study was to develop the SIARG method by modifying the SIMS method, and to confirm the feasibility of this method.
Methods:
The correlation between the input counts of the SIARG method and the blood counts was determined by linear regression analysis. The rCBF values determined by the SIARG method were compared with the values obtained with the ARG and SIMS methods.
Results:
There was a good linear correlation between the SIARG counts and the arterial blood counts obtained by the ARG method (r=0.85, P<0.001, n=29). The rCBF values obtained by the ARG and SIARG methods (n=29, 696 ROIs) correlated well (y=1.01x - 3.6, r=0.85, P<0.001). Similarly, the rCBF values obtained by the SIARG and SIMS methods (n=29, 696 ROIs) correlated well (y=0.98x - 15.2, r=0.90, P<0.001). rCBF values obtained by the SIARG method were almost the same as the values obtained by the ARG method, and values of the SIMS method were 15 ml/100g/min higher that of those obtained by the SIARG method.
Conclusion:
The rCBF values obtained by the ARG, SIARG, and SIMS methods correlated very well. Therefore, the SIARG method is potentially useful for examinations in routine clinical practice.
Related Concept Videos
Simple Pendulum
The period of a simple pendulum depends on two factors: its length and the acceleration due to gravity. The period is completely independent of any other factors, such as mass or maximum displacement. For small displacements, a pendulum is...
Simple Trusses
The most basic planar truss is a simple truss with three members arranged in a triangular formation. This triangular truss is inherently stable and rigid due to its geometry, making it an ideal starting point for creating more...
Simple Harmonic Motion
Development of Analytical Methods
Simple Staining Technique
Derivatives of Simple Functions