Related Experiment Video
Updated: Feb 15, 2026

Photostimulation by Femtosecond Laser Activates Extracellular-signal-regulated Kinase ERK Signaling or Mitochondrial Events in Target Cells
Published on: July 6, 2019
Comparison of 2 laser fragmentation patterns used in femtosecond laser-assisted cataract surgery
Mehdi Shajari1, Sherin Khalil1, Wolfgang J Mayer1
1From the Department of Ophthalmology (Shajari, Khalil, Al-Khateeb, Böhm, Petermann, Hemkeppler, Kohnen), Goethe University, Frankfurt am Main, and the Department of Ophthalmology (Mayer), Ludwig Maximilians University, Munich, Germany.
Purpose:
To evaluate the effect of fragmentation patterns (pie pattern versus grid pattern) on effective phacoemulsification time (EPT).
Setting:
Department of Ophthalmology, Goethe University, Frankfurt am Main, Germany.
Design:
Retrospective case series.
Methods:
Eyes that had femtosecond laser-assisted cataract surgery were included. One half of the group was treated with the pie pattern. The preoperative lens density was evaluated by Scheimpflug imaging (Pentacam). Then, the eyes treated with the grid pattern were matched to the pie-pattern group based on lens density (Scheimpflug imaging).
Results:
The study comprised 150 eyes (75 in the pie-pattern group and 75 in the grid pattern group). The mean patient age was 66 years ± 10.67 (SD). The Scheimpflug density zone was 10.05% ± 1.52%. The mean EPT was 6.63 ± 5.41 seconds for the pie pattern, significantly higher than the 4.26 ± 6.99 seconds for the grid pattern (P < .01, Wilcoxon rank-sum test). The number of eyes with EPT = 0 was significantly higher with grid pattern (37 for grid versus 1 for pie, P < .01, χ2 test). Regression analysis showed that the EPT was significantly dependent on lens density for both methods (P = .045 for pie versus P < .01 for grid). In eyes with a lens density higher than 12% (9 eyes in each group), the pie pattern showed significantly lower EPT (P = .02, Wilcoxon rank-sum test).
Conclusions:
In cases of low to moderate lens density, grid fragmentation pattern should be used because the EPT was significantly lower and a significantly higher number of eyes did not require further emulsification. However, in eyes with high density (>12%), pie-pattern fragmentation is recommended.
Related Concept Videos
Matrix-Assisted Laser Desorption Ionization (MALDI)
Habitat Fragmentation
The Sense of Self: Reflected Self-Appraisal and Social Comparison
Fixed Action Patterns
Multiple Comparison Tests
It would be easy to compare two samples using a significance alpha level of 0.05. In other words, there is only one sample pair to be compared. However, it would be difficult to identify a significantly different sample if the number...
Evolutionary Relationships through Genome Comparisons

