Detection of STEMI Using Prehospital Serial 12-Lead Electrocardiograms

Insights

Serial 12-lead electrocardiograms (ECGs) in ambulances helped identify ST-elevation myocardial infarction (STEMI) in 8% of patients initially showing no STEMI. This prehospital ECG monitoring improves STEMI detection during emergency medical services transport.

Area of Science:

  • Cardiology
  • Emergency Medicine
  • Medical Technology

Background:

  • Serial 12-lead electrocardiograms (ECGs) may enhance the management of ST-segment elevation (STE) or evolving ST-segment elevation myocardial infarction (STEMI) in prehospital settings.
  • Limited scientific evidence currently supports the clinical utility of serial prehospital ECGs for STEMI detection.

Purpose of the Study:

  • To evaluate the effectiveness of serial 12-lead ECGs in detecting STEMI among patients during transport by emergency medical services (EMS) in Canada.

Main Methods:

  • A retrospective study analyzed suspected STEMI patients transported by EMS in Québec, Canada (August 2006 - December 2013).
  • Patients underwent serial 12-lead ECG monitoring with transmission every 2 minutes.
  • ECGs were reviewed by emergency physicians and categorized by persistent or dynamic STE.

Main Results:

  • Of 728 eligible patients, 84.3% had persistent STE, and 15.7% had dynamic STE.
  • Dynamic STE involved 1 ST-segment change in 11.1% and ≥2 changes in 4.5% of patients.
  • STEMI was identified on a subsequent ECG in 8.0% of cases initially showing no STEMI.

Conclusions:

  • Prehospital serial 12-lead ECGs identified STEMI in 8% of patients with an initial non-STEMI ECG by recognizing transient ST-segment changes during transport.
  • This method demonstrates value in improving STEMI detection within emergency medical services.
Abstract

Related Concept Videos

Electrocardiogram01:29

Electrocardiogram

An electrocardiogram (ECG or EKG) is a critical diagnostic tool that records the electrical signals produced by the heart during each heartbeat. This recording is achieved through electrodes placed strategically on the arms, legs, and chest. The electrocardiograph amplifies these signals and produces 12 distinct tracings, offering a comprehensive understanding of the heart's electrical activity.
Three major waveforms are present in a typical ECG recording: the P wave, the QRS complex, and...
6.6K
Electrocardiogram Fundamentals01:28

Electrocardiogram Fundamentals

Introduction
An electrocardiogram (ECG) is a diagnostic tool for identifying cardiac conditions such as arrhythmias, conduction abnormalities, and myocardial ischemia.
Definition
An electrocardiogram (ECG) visualizes the heart's electrical activity by tracing the electrical movement associated with each heartbeat on a graph or monitor. As the heart beats, an electrical wave passes through it, correlating with the cardiac cycle events.
Parts of an ECG
An ECG utilizes electrodes on the skin...
1.6K
Serial Position Effect01:03

Serial Position Effect

The serial position effect is a cognitive phenomenon where individuals are more likely to recall the first and last items in a list compared to those in the middle. This effect is divided into the primacy effect and the recency effect. The primacy effect is observed when the initial items in a list are remembered better. This occurs because these items are rehearsed more frequently or receive more elaborative processing, allowing them to be encoded into long-term memory more effectively. For...
567
Phase-lead and Phase-lag Controllers01:22

Phase-lead and Phase-lag Controllers

Understanding the working function of different types of controllers can be illustrated with practical analogies, such as adjusting a stereo's volume equalizer. Cranking up the bass involves a phase-lead controller, which functions as a high-pass filter, while increasing the treble uses a phase-lag controller, which acts as a low-pass filter. PD controllers, similar to high-pass filters, enhance the system's response to high-frequency components. PI controllers, akin to low-pass...
585
Time and frequency -Domain Interpretation of Phase-lead Control01:24

Time and frequency -Domain Interpretation of Phase-lead Control

Phase-lead controllers are commonly used in various control systems to enhance response speed and stability. Adjusting the brightness on a television screen offers a practical example of phase-lead control. When contrast is enhanced, a phase-lead controller is employed. Mathematically, phase-lead control is identified when the first parameter is smaller than the second.
The design of phase-lead control involves the strategic placement of poles and zeros to balance steady-state error and system...
481
Detection of Gross Error: The Q Test01:00

Detection of Gross Error: The Q Test

When one or more data points appear far from the rest of the data, there is a need to determine whether they are outliers and whether they should be eliminated from the data set to ensure an accurate representation of the measured value. In many cases, outliers arise from gross errors (or human errors) and do not accurately reflect the underlying phenomenon. In some cases, however, these apparent outliers reflect true phenomenological differences. In these cases, we can use statistical methods...
7.1K