Related Experiment Video
Updated: Feb 15, 2026

07:41
Author Spotlight: An Alternative Approach to Protein Quantification by Bradford Assay Using a Smartphone
Published on: September 8, 2023
5.1K
Research on Geometric Calibration of Spaceborne Linear Array Whiskbroom Camera
Qinghong Sheng1, Qi Wang2, Hui Xiao3
1College of Astronautics, Nanjing University of Aeronautics and Astronautics, Nanjing 210016, China. qhsheng@nuaa.edu.cn.
Sensors (Basel, Switzerland)
|January 17, 2018
Summary
This study introduces a new geometric model for spaceborne thermal-infrared cameras, improving land surface temperature retrieval. The model achieves high positioning accuracy, even without ground control points.
Area of Science:
- Earth Observation
- Remote Sensing Technology
- Geospatial Calibration
Background:
- Accurate geographic coordinates are crucial for land surface temperature (LST) retrieval using spaceborne thermal-infrared cameras.
- High spatial resolution and wide coverage are desired for effective Earth imaging.
- Linear array whiskbroom Charge-Coupled Device (CCD) arrays enable broad-area imaging with high resolution.
Purpose of the Study:
- To propose a novel geometric model for spaceborne linear-array-scanning imaging.
- To calibrate temporal system and whiskbroom angle parameters for improved accuracy.
- To enhance the geometric accuracy of thermal-infrared imagery for LST retrieval.
Main Methods:
- Development of a spaceborne linear-array-scanning imaging geometric model.
- Focus on whiskbroom characteristics: equal time intervals and unequal angles.
- Calibration of temporal system and whiskbroom angle parameters.
Main Results:
- Experimental calibration and verification using China's YG-14 satellite.
- Achieved plane positioning accuracy better than 30 pixels without ground control points (GCPs).
- Achieved plane positioning accuracy better than 1 pixel with GCPs.
Conclusions:
- The proposed geometric model effectively calibrates spaceborne thermal-infrared cameras.
- High positioning accuracy is attainable, significantly benefiting LST retrieval.
- The model demonstrates robust performance, with or without GCPs.
Related Concept Videos
Calibration Curves: Linear Least Squares
4.6K
A calibration curve is a plot of the instrument's response against a series of known concentrations of a substance. This curve is used to set the instrument response levels, using the substance and its concentrations as standards. Alternatively, or additionally, an equation is fitted to the calibration curve plot and subsequently used to calculate the unknown concentrations of other samples reliably.
For data that follow a straight line, the standard method for fitting is the linear...
For data that follow a straight line, the standard method for fitting is the linear...
4.6K
Geometric Mean
4.1K
The mean is a measure of the central tendency of a data set. In some data sets, the data is inherently multiplicative, and the arithmetic mean is not useful. For example, the human population multiplies with time, and so does the credit amount of financial investment, as the interest compounds over successive time intervals.
In cases of multiplicative data, the geometric mean is used for statistical analysis. First, the product of all the elements is taken. Then, if there are n elements in the...
In cases of multiplicative data, the geometric mean is used for statistical analysis. First, the product of all the elements is taken. Then, if there are n elements in the...
4.1K
Geometric Sequences
298
In systems where values diminish by a constant proportion at each stage, the resulting sequence follows a geometric structure. Each new value in the sequence is obtained by applying a fixed multiplier to the preceding term. This regular, proportional decline type is often used to represent processes involving gradual loss, such as energy dissipation or reduction in amplitude over time.When analyzing the total effect of such a process across unlimited iterations, the series of values is referred...
298
Glassware Calibration
1.5K
Accurate calibration of glassware, such as volumetric flasks, pipettes, and burettes, is essential to ensure accurate measurements in the analytical laboratory. Calibration helps maintain consistency across measurements and prevents errors arising from inaccurate volumes.
Volumetric flasks: Volumetric flasks are designed to prepare aqueous solutions of precise volumes accurately with a calibration line on the neck. To calibrate a volumetric flask, it is important to fill it with distilled...
Volumetric flasks: Volumetric flasks are designed to prepare aqueous solutions of precise volumes accurately with a calibration line on the neck. To calibrate a volumetric flask, it is important to fill it with distilled...
1.5K
Instrument Calibration
805
Instrument calibration is essential for ensuring that instruments produce accurate and consistent results. It is vital in manufacturing, healthcare, testing laboratories, and scientific research. Calibration processes are specific to each instrument and help enhance data accuracy. Each instrument has a unique calibration process tailored to its design and function to improve data accuracy.
Analytical Balance Calibration
An analytical balance measures mass and requires regular calibration to...
Analytical Balance Calibration
An analytical balance measures mass and requires regular calibration to...
805
Linear Equations
519
Linear equations form the foundation of many algebraic and real-world applications, characterized by their simplicity and utility. A linear equation is an algebraic statement in which each term is either a constant or a product of a constant and a single variable. These equations represent straight lines when plotted on a Cartesian coordinate plane, reflecting a constant rate of change between two quantities.A typical linear equation in one variable has the form: ax + b = c, where a, b, and c...
519

