Real time optic nerve sheath diameter measurement during lumbar puncture
Getaw Worku Hassen1, Mohammed Al-Juboori2, Barbara Koppel3
1NYMC, Metropolitan Hospital Center, Department of Emergency Medicine, New York, NY, United States.
The American Journal of Emergency Medicine
|January 18, 2018
Summary
Point of care ultrasound measurement of optic nerve sheath diameter (ONSD) can assess intracranial pressure (ICP). This study demonstrates dynamic ONSD changes during lumbar puncture in a patient with idiopathic intracranial hypertension (IIH).
Area of Science:
- Neurology
- Medical Imaging
- Ultrasound Technology
Background:
- Optic nerve sheath diameter (ONSD) ultrasound is a non-invasive method to estimate intracranial pressure (ICP).
- Previous studies have correlated ONSD measurements with direct ICP monitoring and after interventions like lumbar puncture (LP) and ventricular shunts.
- Idiopathic intracranial hypertension (IIH) is a condition characterized by elevated ICP without a clear secondary cause.
Observation:
- This case report details serial ONSD measurements using point of care ultrasound.
- Dynamic changes in ONSD were observed during a lumbar puncture procedure in a patient diagnosed with IIH.
- The study highlights the feasibility of real-time ONSD monitoring during interventions.
Findings:
- Point of care ultrasound accurately measured ONSD, reflecting ICP dynamics.
- Significant ONSD variations were noted correlating with cerebrospinal fluid (CSF) drainage during LP.
- The findings support ONSD ultrasound as a responsive indicator of ICP fluctuations.
Implications:
- Real-time ONSD ultrasound can provide valuable insights into ICP management during procedures like LP.
- This technique may enhance the monitoring of patients with conditions causing raised ICP, such as IIH.
- Point of care ultrasound offers a practical, non-invasive tool for dynamic ICP assessment in clinical settings.
Related Concept Videos
Real Time RT-PCR
65.5K
Real-time reverse transcription-polymerase chain reaction, or Real-time RT-PCR, is an analytical tool used to determine the expression level of target genes. The method involves converting mRNA to complementary DNA with the help of an enzyme known as reverse transcriptase, followed by the PCR amplification of the cDNA. These two processes can be performed simultaneously in a single tube or separately as a two-step reaction.
The real-time quantification of the number of amplified products is...
The real-time quantification of the number of amplified products is...
65.5K
Design Example: Calculating Safe Diameter for Wind-Exposed Disc
365
Assessing safety in wind-exposed installations is crucial to preventing potential failures. This example explores the calculation and design adjustments needed to mount a circular disc on a building facade, where wind forces are a primary concern. A 4-meter diameter disc was initially designed as an aesthetic feature facing winds at a velocity of 25 meters per second, with an air density of 1.25 kilograms per cubic meter. Given these conditions, the drag force on the disc was determined using...
365
Real Number System
1.2K
The real number system includes all numbers used for counting, measuring, and comparing quantities. Natural numbers are the basic counting numbers: 1, 2, 3, and so on. Integers expand this set by including zero and negative whole numbers: ..., –3, –2, –1, 0, 1, 2, .... Rational numbers are those that can be expressed as the ratio of two integers m/n, where n≠0. This includes fractions like 1/2, integers such as 46, and decimals that terminate, such as 0.17, or...
1.2K
Real Number Operations
349
The concept of real numbers includes all the values that can be represented on a continuous number line. The system began with basic counting values used for enumeration. It later expanded to include values that represent the absence of quantity and opposites of the counting values. When situations required expressing parts of a whole or dividing quantities evenly, values capable of representing such proportions were developed. When written using decimal notation, these values can end or repeat...
349
Spinal Nerves: Plexus II
2.5K
The plexuses of the lower body include the lumbar, sacral, and coccygeal plexuses, which innervate the abdomen, pelvis, legs, and coccygeal region. These plexuses control the transmission of sensory information and coordinate motor functions of the lower body.
The Lumbar Plexus
The lumbar plexus is situated within the lumbar region of the back and is primarily formed by the first four lumbar spinal nerves (L1 to L4). This plexus extends its branches into several nerves, including the...
The Lumbar Plexus
The lumbar plexus is situated within the lumbar region of the back and is primarily formed by the first four lumbar spinal nerves (L1 to L4). This plexus extends its branches into several nerves, including the...
2.5K
Nerve Supply of the GI Tract
3.7K
The neuronal supply to the gastrointestinal (GI) tract is essential for regulating various functions, including digestion, absorption, and movement of food. This intricate network of nerves is known as the enteric nervous system (ENS), often referred to as the "second brain" of the body.
The enteric nervous system consists of two major plexuses: the myenteric plexus (Auerbach's plexus) and the submucosal plexus (Meissner's plexus). These plexuses are located within the layers of...
The enteric nervous system consists of two major plexuses: the myenteric plexus (Auerbach's plexus) and the submucosal plexus (Meissner's plexus). These plexuses are located within the layers of...
3.7K