Meta-analysis of the Sources of Bleeding after Adult Cardiac Surgery

Fausto Biancari1, Eeva-Maija Kinnunen2, Tuomas Kiviniemi3

  • 1Department of Surgery, University of Turku, Turku, Finland; Department of Surgery, University of Oulu, Oulu, Finland; Heart Center, Turku University Hospital and University of Turku, Turku, Finland.

Abstract

Related Concept Videos

Mesh Analysis with Current Sources01:10

Mesh Analysis with Current Sources

Mesh analysis becomes simpler when analyzing circuits with current sources, whether independent or dependent. The presence of current sources reduces the number of equations required for analysis. Two cases illustrate this:
Current Source in One Mesh: The analysis process is straightforward when a current source is found in only one mesh within the circuit. Mesh currents are assigned as usual, with the mesh containing the current source excluded from the analysis. Kirchhoff's voltage law...
2.1K
Nodal Analysis with Voltage Sources01:11

Nodal Analysis with Voltage Sources

Nodal analysis is a remarkably effective method used in electrical engineering to simplify the analysis of complex circuits, including those with dependent or independent voltage sources. Its strength lies in its systematic approach to breaking down circuits into manageable components, making it easier for engineers to understand and solve.
Consider a circuit that contains four resistors and two voltage sources, as shown in Figure 1. One of these voltage sources is connected between a...
2.0K
Bleeding in Fresh Concrete01:22

Bleeding in Fresh Concrete

Bleeding in fresh concrete occurs when water from the mix rises to the surface. This happens because the mix's solid components fail to retain all the water as they settle, leading to separation where water collects at the top. The severity of bleeding can be measured by assessing the total settlement or by noting the decrease in height per unit height of concrete.
Bleeding can cause several issues in the concrete structure. Sometimes, the rising water gets trapped beneath large aggregate...
625
Directing Effect of Substituents: meta-Directing Groups01:09

Directing Effect of Substituents: meta-Directing Groups

Substituents on the benzene ring that direct an incoming electrophile to undergo substitution at the meta position are called meta directors. All meta directors either have a positive charge on the atom directly bonded to the ring or a partial positive charge. These groups function by withdrawing electrons from the ring through inductive and resonance effects. Consider the carbocation intermediates formed upon the addition of an electrophile on nitrobenzene at the...
6.1K
Sinusoidal Sources01:18

Sinusoidal Sources

Direct current (DC) refers to an electric current that flows in a single direction, maintaining a constant polarity. This is in contrast to alternating current (AC), which periodically changes its direction and magnitude. AC forms the backbone of modern electricity transmission and distribution systems due to its efficient long-distance transmission capabilities.
In homes, the power supplies use sinusoidal sources to provide electricity. These sources generate a voltage that varies sinusoidally...
1.2K
AC Sources01:20

AC Sources

Direct current is a flow of electric charge in only one direction and has a steady state of constant voltage in the circuit. Rectifiers, batteries, commutator-equipped generators, and fuel cells are some examples of devices that generate direct current. Nowadays, most applications use a time-varying voltage source. Alternating current is a flow of electric charge that periodically reverses direction. An alternating current is produced by an alternating emf that is generated in a power plant. If...
4.2K