Treatment with 48-mm everolimus-eluting stents : Procedural safety and 12-month patient outcome
C K Tan1, Z L Tin1, M K M Arshad1
1Tan Tock Seng Hospital, 11 Jalan Tan Tock Seng, 308433, Singapore, Singapore.
Background:
Lesion length is a major predictor of adverse outcomes after percutaneous coronary intervention. Long lesions often require multiple stents with variable overlap, which increases the probability of geographical miss and the incidence of mechanical complications, such as side-branch occlusion, restenosis, and stent thrombosis. These pitfalls may be avoided by use of an ultra-long device.
Methods:
We retrospectively assessed the performance of the 48-mm Xience Xpedition everolimus-eluting stent (EES) at our institution.
Results:
A total of 123 patients (mean age: 60.94 years, n = 93 [76%] male) with 129 lesions were identified. Lesions (n = 69, 53.5%) were located in the left anterior descending artery, the right coronary artery (n = 47, 36.4%), and the circumflex artery (n = 8, 6.2%); 83 lesions involved a major side branch. The majority were treated with a provisional single-stent strategy. Other characteristics included significant tortuosity in 15 lesions (11.6%) and moderate-to-heavy calcification in 46 lesions (35.7%). In all cases, balloon pre-dilatation was performed before stent insertion. Successful delivery and deployment of the 48-mm EES device was achieved in 100% of the patients. The mean number of stents per lesion was 1.4, while the mean total stent length was 58 ± 17.3 mm and mean stent diameter, 3.00 ± 0.67 mm. The procedural success rate was 99.2%. The 30-day major cardiac adverse event (MACE) rate was 0.8%, while the 12-month MACE was 3.3%.
Conclusion:
The Xience 48-mm EES device appears to be safe and efficacious with a low clinical event rate at the 12-month follow-up. Where feasible, this would support the use of the ultra-long 48-mm platform in lieu of multiple overlapping shorter devices.
More Related Videos
11:07Biodegradable Magnesium Stent Treatment of Saccular Aneurysms in a Rat Model - Introduction of the Surgical Technique
Published on: October 1, 2017
14:38Preparation, Procedures and Evaluation of Platelet-Rich Plasma Injection in the Treatment of Knee Osteoarthritis
Published on: January 4, 2019
Related Concept Videos
Survey Safety
High-Performance Liquid Chromatography: Elution Process
Predicting Reaction Outcomes
Outcomes of Glycolysis
Cellular respiration can occur aerobically (with oxygen) or anaerobically (without oxygen). In the presence of oxygen, cellular respiration starts with glycolysis and continues with pyruvate...
Household Wiring And Electrical Safety
Guidelines for Writing Outcome
Patient outcomes reflect the patient's response to the goal rather than what the nurse aims to achieve. Terminology should be observable and measurable to avoid the reader's interpretation. The desired outcome should be realistic and achievable in the designated care timeframe. Expected outcomes should align with adjunctive therapies. The outcome should enhance care...