Aptamer-Directed Specific Drug Delivery and Magnetic Resonance Imaging of Renal Carcinoma Cells In Vitro and In Vivo

Related Concept Videos

Magnetic Resonance Imaging01:24

Magnetic Resonance Imaging

Magnetic resonance imaging (MRI) is a noninvasive medical imaging technique based on a phenomenon of nuclear physics discovered in the 1930s, in which matter exposed to magnetic fields and radio waves was found to emit radio signals. In 1970, a physician and researcher named Raymond Damadian noticed that malignant (cancerous) tissue gave off different signals than normal body tissue. He applied for a patent for the first MRI scanning device in clinical use by the early 1980s. The early MRI...
9.9K
Imaging Studies IV: Magnetic Resonance Imaging01:27

Imaging Studies IV: Magnetic Resonance Imaging

Introduction:Magnetic Resonance Imaging, or MRI, can include a specialized imaging technique of the urinary system known as Magnetic Resonance Urography (MRU). This radiation-free technique uses strong magnetic fields and radio waves to produce detailed images with the help of a computer. MRU is particularly effective for visualizing fluid-filled structures like the kidneys, ureters, and bladder.Applications of MRI in the Genitourinary SystemKidneys and Ureters: MRI detects tumors, cysts,...
296
Drug Product Performance: In Vitro–In Vivo Correlation01:20

Drug Product Performance: In Vitro–In Vivo Correlation

In pharmaceutical development, it's crucial to establish a predictive in vitro–in vivo correlation (IVIVC) for two or more formulations to gain a comprehensive understanding of release properties. IVIVC reduces the need for costly in vivo studies and facilitates the establishment of meaningful dissolution specifications with significant cost savings and decreased regulatory burden. Furthermore, a meaningful IVIVC should predict Cmax and AUC within 20%, aligning with FDA guidance while...
288
Atomic Nuclei: Magnetic Resonance01:05

Atomic Nuclei: Magnetic Resonance

The number of nuclear spins aligned in the lower energy state is slightly greater than those in the higher energy state. In the presence of an external magnetic field, as the spins precess at the Larmor frequency, the excess population results in a net magnetization oriented along the z axis. When a pulse or a short burst of radio waves at the Larmor frequency is applied along the x axis, the coupling of frequencies causes resonance and flips the nuclear spins of the excess population from the...
1.2K
Renal Drug Clearance: Comparison Between Renal Excretion Methods01:08

Renal Drug Clearance: Comparison Between Renal Excretion Methods

Renal clearance is a critical parameter encompassing kidney filtration, secretion, and reabsorption processes. It is calculated using a specific equation to determine the rate at which the kidneys clear a drug.
Renal clearance is often associated with the renal glomerular filtration rate (GFR), which represents the rate at which plasma is filtered through the glomeruli in the kidney. When drug reabsorption is minimal and there is no active secretion, renal clearance is closely related to the...
660
Drug Elimination: Non-Renal Routes01:23

Drug Elimination: Non-Renal Routes

The liver plays a pivotal role in eliminating drugs and their metabolites, primarily through a process known as biliary excretion. This process involves the hepatocytes, the primary cells in the liver that generate bile. A range of transporters actively expels polar drugs or hydrophilic drug metabolites into the bile, which transports the drugs and metabolites into the small intestine. From here, they are eventually expelled from the body through feces. In some instances, the original drug or a...
3.4K