Maternal T-cell engraftment impedes with diagnosis of a SCID-ADA patient

Arnalda Lanfranchi1, Vassilios Lougaris2, Lucia Dora Notarangelo3

  • 1Stem Cell Laboratory, Section of Hematology and Blood Coagulation, Clinical Chemistry Laboratory, Diagnostics Department, ASST Spedali Civili of Brescia, Brescia, Italy.

We describe the case of a child affected by severe combined immunodeficiency (SCID) with adenosine deaminase (ADA) deficiency showing a maternal T-cell engraftment, a finding that has never been reported before. The presence of engrafted maternal T cells was misleading. Although ADA enzymatic levels were suggestive of ADA-SCID, the child did not present the classical signs of ADA deficiency; therefore, the initial diagnosis was of a conventional SCID. However, ADA toxic metabolites and molecular characterization confirmed this diagnosis. Polyethylene glycol-modified bovine (PEG) ADA therapy progressively decreased the number of maternal engrafted T cells. The child was grafted with full bone marrow from a matched unrelated donor, after a reduced conditioning regimen, and the result was the complete immunological reconstitution.

Related Concept Videos

Nursing Process for Patient and Caregiver Teaching I: Assessment and Diagnosis01:24

Nursing Process for Patient and Caregiver Teaching I: Assessment and Diagnosis

The nursing process provides a clinical decision-making framework for patients and families to establish and implement a personalized care plan. Since part of the nurse's duties is to teach patients, the steps of the nursing process are the most effective way to approach instruction. The nursing process and the teaching-learning process are inextricably linked.
It is critical to determine the patient's learning needs during the assessment. Determination of learning needs compounds data...
2.5K
Impedance Combination01:21

Impedance Combination

Consider a string of christmas lights, each bulb symbolizing an impedance element. In this series configuration, the flow of electric current remains uniform across every component. This behavior aligns with Kirchhoff's Voltage Law (KVL), which asserts that the total impedance in such a setup equals the sum of individual impedances—akin to resistors in series. It follows that the voltage from the power source is distributed proportionally among these components, adhering to the voltage...
764
Impedances and Admittance01:23

Impedances and Admittance

In the realm of AC circuits, passive circuit elements like resistors, inductors, and capacitors take on a different character when characterized by phasor voltage and current. Their behavior is expressed through impedance, a vital concept in AC circuit analysis.
Impedance is a measure of resistance to sinusoidal current flow in an AC circuit. Unlike their behavior in DC circuits, where inductors appear as short circuits and capacitors as open circuits, the behavior of these components in AC...
1.9K
Nursing Diagnosis01:22

Nursing Diagnosis

Following assessment, a nursing diagnosis is the next step in the nursing process. It begins after the nurse has collected and recorded the patient data. The purpose of diagnosing is to identify how the client responds to actual or potential health processes, identify factors that bestow or that cause health problems, the etiologies, and identify resources or strengths the individual, group, or community can draw on to prevent or resolve problems.
The nursing diagnosis focuses on evidence-based...
4.3K
Series Impedances: Three-Phase Line01:27

Series Impedances: Three-Phase Line

Calculating series impedances for a three-phase overhead line involves evaluating resistances and inductive reactances in a network with three-phase and multiple neutral conductors grounded at regular intervals.
Using Kirchhoff's laws, an integro-differential equation for the network is derived. This equation accounts for unbalanced phase currents, which may induce return currents through neutral wires and the earth, seeking the least impedance path. Earth return conductors can replace the...
455
Bus Impedance Matrix01:24

Bus Impedance Matrix

Calculating subtransient fault currents for three-phase faults in an N-bus power system involves using the positive-sequence network. When a three-phase short circuit occurs at a specific bus, the analysis uses the superposition method to evaluate two separate circuits.
In the first circuit, all machine voltage sources are short-circuited, leaving only the prefault voltage source at the fault location. The positive-sequence bus impedance matrix can be determined by solving the nodal equations,...
541