Binding of vanadium to human serum transferrin - voltammetric and spectrometric studies

Cristina G Azevedo1, Isabel Correia1, Margarida M C Dos Santos1

  • 1Centro de Química Estrutural, Instituto Superior Técnico, Universidade de Lisboa, Av. Rovisco Pais, 1049-001 Lisboa, Portugal.

Related Concept Videos

The Early Endosome: Endocytosis of Transferrin01:28

The Early Endosome: Endocytosis of Transferrin

Essential proteins such as insulin or low-density lipoprotein (LDL) and micronutrients such as iron enter a eukaryotic cell through receptor-mediated endocytosis. Subsequently, the early endosomes fuse with the vesicles containing such receptor-ligand complexes and play a vital role in sorting the incoming ligands and receptors. While the ligands are either degraded inside the vesicle or released into the cytosol, their receptors are returned to the plasma membrane for further rounds of...
4.9K
Voltammetric Techniques: Pulse Voltammetry01:17

Voltammetric Techniques: Pulse Voltammetry

Differential-pulse voltammetry (DPV) is a type of voltammetry that involves applying a series of voltage pulses to an electrochemical cell while measuring the resulting current. In DPV, the differential pulse or small potential pulses are superimposed on a linear potential sweep. The magnitude of these pulses is typically small, often in the millivolt range. Each voltage pulse lasts a short duration, usually in the order of a few milliseconds, and is applied at regular intervals along the...
1.6K
Serum Studies: Renal Function Tests01:24

Serum Studies: Renal Function Tests

Renal function tests are crucial for assessing kidney health, monitoring disease progression, and evaluating the kidneys' efficiency in waste elimination, fluid balance, and electrolyte regulation. These tests offer critical insights into kidney function, even though routine measurements may appear normal until there is a significant decline in the glomerular filtration rate or GFR. Typically, signs of kidney impairment only become evident when the GFR falls to about 50% of its normal level.
464
Serum Laboratory Studies, Stool Test, Breath Test01:30

Serum Laboratory Studies, Stool Test, Breath Test

Gastrointestinal (GI) diagnostic studies are pivotal in confirming, ruling out, diagnosing, or staging various diseases, including cancers. Following diagnosis, allocating time for discussions with the patient and providing informational resources is crucial. Diagnostic assessments of the GI tract often occur in outpatient settings like endoscopy suites or GI labs. Preparation for these tests may include dietary restrictions, fasting, liquid bowel preparations, laxatives, enemas, and the...
918
Voltammetric Techniques: Cyclic Voltammetry01:10

Voltammetric Techniques: Cyclic Voltammetry

Cyclic voltammetry (CV) is an electrochemical technique used to investigate the redox properties of a chemical species. It involves measuring the current response of an electrochemical cell as a function of the applied potential. The setup for cyclic voltammetry typically consists of a working electrode, a reference electrode, and a counter electrode—all immersed in an electrolyte solution. The working electrode is where the redox reaction of interest occurs, while the reference electrode...
1.6K
Voltammetric Techniques: Linear-Scan (E vs Time)01:12

Voltammetric Techniques: Linear-Scan (E vs Time)

Polarography is a classical voltammetric technique used to analyze electrochemical reactions. This method applies a linear potential sweep to a dropping mercury electrode (DME), and the resulting current is measured. A dropping mercury electrode is commonly used as the working electrode in polarography. It consists of a capillary tube filled with mercury, where the tiny droplet forms at the tip. This droplet continuously drops from the capillary, creating a new electrode surface for each...
1.3K