Related Experiment Video
Updated: Feb 15, 2026

Proton Therapy Delivery and Its Clinical Application in Select Solid Tumor Malignancies
Published on: February 6, 2019
Feasibility study of range-based registration using daily cone beam CT for intensity-modulated proton therapy
Weiguang Yao1, Matthew J Krasin1, Jonathan B Farr1
1Department of Radiation Oncology, St. Jude Children's Research Hospital, 262 Danny Thomas Place, Memphis, TN, 38105, USA.
Purpose:
Proton dose coverage is sensitive to proton beam range. The current practice of CT number-based registration for patient positioning focuses on matching the target and is not sufficient for proton therapy because the proton range depends on the medium traversed by the beam. Patient body deformations and anatomical changes result in range deviation in the target. We propose proton range-based registration to minimize the range deviation.
Methods:
The range was calculated from cone beam-computed tomography (CBCT) of the patient on couch, and the range deviation was the difference of the calculated range from that on the initial (day 1) CBCT. In the investigated prostate cases in which the main cause of range deviation was the rotation of femur bones, and in the investigated abdomen cases in which the main cause of range deviation was body growth and anatomic change, our range-based registration was used to obtain the optimal beam angle by minimizing the range deviation. The new angle was limited to be ±5° from that planned to prevent potentially increased dose to the organs at risk. To demonstrate the benefit of range-based registration, we investigated the range at the voxels on the surface of the target volume. The calculation error of range deviation due to CBCT scatter was investigated by using solid water phantoms with different thicknesses. Range-based registration using both CBCTs and CTs was performed in cases of two patients with pelvic rhabdomyosarcoma and one patient with upper abdominal tumor. The range was represented by the water-equivalent thickness to shorten the computation for online application purposes.
Results:
In the phantom study, the calculation error of range deviation due to CBCT scatter was within 2 mm for a 1-cm thickness change (the mean range deviation was 0.8 mm). In the CT study of the prostate cases, the range deviation (mean ± root-mean-square deviation) on the contour in each slice was efficiently reduced from 3.6 ± 2.8 mm to 2.1 ± 1.4 mm, with most slices being within 3 mm; in the CT study of the abdomen cases, the range deviation of the whole set was reduced from 4.4 ± 1.9 mm to 3.5 ± 2.1 mm. Both the mean and root-mean-square deviation of the range deviation on each treatment day were decreased. The dose coverage on the target was improved and the dose on the OARs was only slightly changed.
Conclusion:
Range-based registration can efficiently mitigate range deviation due to patient positioning and anatomical changes. It can shorten patient positioning time and reduce the patient's dose from CBCT.
Related Concept Videos
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...
Imaging Studies for Cardiovascular System V: CT
Range
15.9; 16.1; 15.2; 14.8; 15.8; 15.9; 16.0; 15.5
Measurements of the amount of soda in a 16-ounce can vary since different subjects record these measurements or since the exact amount - 16 ounces of liquid, was not...
Imaging Studies for Cardiovascular System VI: Calcium -Scoring CT
Beams
Based on geometry, beams can be straight, tapered, or curved. Straight beams are the most common type and have a constant cross-section throughout their length. Tapered beams, on the other hand, have a varying cross-section along...
Classical Conditioning in Daily Life
John B. Watson and Rosalie Rayner famously demonstrated the development of fear through classical conditioning in their experiment with Little Albert. They paired the...