Objective:
The relationship between multiple semiquantitative indices on technetium-99m metoxyisobutylisonitrile (Tc-99m MIBI) parathyroid single-photon emission computed tomography (SPECT) and clinical, laboratory, and radiological data was investigated in primary hyperparathyroidism.
Patients And Methods:
Ninety-three patients who had a histopathologically confirmed single parathyroid adenoma (PT) were enrolled. Regions of interests were drawn around the PT, neighboring thyroid (T), and background in early and late planar images and isocontour regions of interests around the adenoma in SPECT images (PT SPECT). The relationships between early and late PT, parathyroid adenoma counts/neighboring thyroid counts, parathyroid counts-thyroid counts (PT-T), PT washout, retention index, PT SPECT and serum parathormone (PTH), Ca, P, urinary Ca levels, weight of the adenoma, neck ultrasonography, renal ultrasonography, and bone mineral density findings were investigated.
Results:
There was a positive correlation between the weight of the adenoma and serum PTH and calcium (Ca) levels (P<0.001), between serum PTH and Ca levels (P<0.001), early PT-T and serum Ca levels (P=0.027), late PT-T and weight of the adenoma (P=0.04), and PT SPECT and serum Ca levels (P=0.046) and a reverse correlation between PT SPECT and serum phosphorus (P) levels (P=0.04). Serum Ca levels were significantly higher and P levels were lower in the group with PT SPECT values above 116. PT SPECT and late parathyroid adenoma counts/neighboring thyroid counts values were significantly higher in the group with serum Ca levels of more than 11 mg/dl. Femoral T and Z scores were significantly lower in patients with lower PT washout. Early PT was significantly lower in patients with coexisting thyroiditis compared with patients with both thyroiditis and thyroid nodules (P=0.034).
Conclusion:
Semiquantitative evaluation of a Tc-99m MIBI parathyroid SPECT study may help predict disease severity in primary hyperparathyroidism.
More Related Videos
09:49Dual-phase Cone-beam Computed Tomography to See, Reach, and Treat Hepatocellular Carcinoma during Drug-eluting Beads Transarterial Chemo-embolization
Published on: December 2, 2013
10:54Preparation and Evaluation of 99mTc-labeled Tridentate Chelates for Pre-targeting Using Bioorthogonal Chemistry
Published on: February 4, 2017
Related Concept Videos
Imaging Studies III: Computed Tomography
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body...
Inductance: Single-Phase And Three-Phase Line
Single-Phase Two-Wire Line:
A single-phase line consists of two solid cylindrical conductors, denoted as x and y. Each conductor carries phasor currents ix and iy, respectively. Given that the sum of these currents is...
Capacitance: Single-Phase And Three-Phase Line
Single-Phase Lines
Consider a single-phase, two-wire transmission line with equal phase spacing energized by a voltage source. One conductor carries a uniform positive charge, while the other carries an equal negative charge. The capacitance C of the line can be derived from the voltage V between the conductors. For a one-meter section of the line, the capacitance is given...