Related Experiment Video
Updated: Feb 15, 2026

A Modeling and Simulation Method for Preliminary Design of an Electro-Variable Displacement Pump
Published on: June 1, 2022
A comparison of group sequential and fixed sample size designs for bioequivalence trials with highly variable drugs
Sophie I E Knahl1, Benjamin Lang1, Frank Fleischer1
1Boehringer Ingelheim Pharma GmbH & Co. KG, Birkendorfer Straße 65, 88397, Biberach, Germany.
Purpose:
A drug is defined as highly variable if its intra-individual coefficient of variation (CV) is greater than or equal to 30%. In such a case, bioequivalence may be assessed by means of methods that take the (high) variability into account. The Scaled Average Bioequivalence (SABE) approach is such a procedure and represents the recommendations of FDA. The aim of this investigation is to compare the performance characteristics of classical group sequential designs (GSD) and fixed design settings for three-period crossover bioequivalence studies with highly variable drugs, where the SABE procedure is utilized.
Methods:
Monte Carlo simulations were performed to assess type I error rate, power, and average sample size for GSDs with Pocock's and O'Brien-Fleming's stopping rules and various timings of the interim analysis and for fixed design settings.
Results:
Based on our investigated scenarios, the GSDs show comparable properties with regard to power and type I error rate as compared to the corresponding fixed designs. However, due to an advantage in average sample size, the most appealing design is Pocock's approach with interim analysis after 50% information fraction.
Conclusions:
Due to their favorable performance characteristics, two-stage GSDs are an appealing alternative to fixed sample designs when assessing bioequivalence in highly variable drugs.
Related Concept Videos
Bioequivalence of Drugs: Drugs with Multiple Indications
Bioequivalence Experimental Study Designs: Completely Randomized and Randomized Block Designs
Sample Size Calculation
The sample size for the given experiment or sampling effort is fundamental to any study design. Sample size decides the number of...
Bioequivalence Experimental Study Designs: Repeated Measures, Cross-Over, Carry-Over, and Latin Square Designs
One-Way ANOVA: Equal Sample Sizes
Different sample means can result in different values for the variance estimate: variance between samples. This is because the variance between samples is calculated as the product of the sample size and the variance between the...
One-Way ANOVA: Unequal Sample Sizes

